Descargar Imprimir esta página

Movement GO5 Manual Del Propietário página 84

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE
PROBLEM
3 - E2
5 - E4
Communication with the
6 - E5
treadmill was interrupted
Under voltage protection
7 - E6
ERROR
Controller overload
failure
Unstable motor
SOLUTION
Remove the equipment from the
outlet. Add 15-20ml of lubricant
according to the instructions for
lubrication described in this manual.
Remove the controller cable and
reconnect it to eliminate the error.
If the error persists, replace the
controller.
Remove the equipment from the
outlet. Check that the motor cable is
well connected or that the power
voltage is stable. If the
problem persists, replace the motor.
Remove the equipment from the
outlet. Check that the motor cable is
well connected or that the power
voltage is stable. If the
problem persists, replace the motor..
Check that if the voltage is less than
200V, if it is less than 200V, check that
the power supply. The normal voltage
of work is 220V ± 10%. If the voltage
is normal, the controller needs to be
39
replaced.