INSTALLATION
INSTRUCTIONS
31
Ins'l'allation
test
(Exhaust
check)
(cont.)
. Check the Error Code before you call for service
Err0r Code
tEl or rE2
. Temperature
sensor failure
. Turn off the dryer and call for
service.
HS
. Humidity
Sensor failure.
. Turn off the dryer and call for
service.
PSor PFor nP
. Electric dryer power cord is not
connected
correctly, or house power
supply is incorrect.
. House fuse is blown, circuit breaker has
tripped, or power outage
has occurred.
. Check the power supply or the
connection of power cord to the
terminal block. Refer to the Connecting
Electric Dryers section of this manual
for complete instructions.
• Reset circuit breaker or replace fuse.
Do not increase the fuse capacity.
If the problem is a circuit overload,
have it corrected by a qualified
electrician.
• Check the duct condition
If the test displays four bars, check the exhaust system for re-
strictions
and damage. Repair or replace the exhaust
system as
needed.
..... @ NOTE
When thedryer is first installed,
this t est shouldbe performed
toalert y ou toanyexisting problemswiththeexhaust ductin
your home. However, since thetest performedduring normal
operation p rovides m ore accurate i nformation on thecondi-
tionoftheexhaustductthandoestheinstallation
test, the
number ofbarsdisplayed d uring thetwo tests m ay notbe the
same.
Do not interrupt
the test cycle, as this could result in the wrong
results.
Even if no bars are displayed during the test cycle, some
restrictions may still be present in the exhaust system. Refer to
the
Venting the Dryer section of this manual for complete exhaust
system and venting requirements.
Restricted or Blocked Airflow
[]
Avoid long runs or runs with multiple elbows or
bends.
Excessor crushed
transition duct
Too many elbows or
exhaust too long
Check for blockages and lint buildup.
Make sure the ductwork
is not crushed or restricted.
Crushed or
damaged
exhaust