BTL BNC_ 00- _ _ _ _ -B15A _010-000S92 / BTL ZNC_ 00- _ _ _ _ -B15A _010-000S92
Magnetostrictive Linear Position Sensor – Rod Style
The CE Mark verifies
that our products meet the requirements
of the current EU Directive.
About this guide
This guide provides all the information required for the
installation and connection of the BTL magnetostrictive
linear position sensor with analog current and voltage
interface.
It applies to the following models:
BTL BNC_ 00- _ _ _ _ -B15A _010-000S92
–
BTL ZNC_ 00- _ _ _ _ -B15A _010-000S92
–
Other applicable documents
A comprehensive user's guide and additional information
about this product can be found at www.balluff.com on
the product page.
Intended use
The BTL magnetostrictive linear position sensor, together
with a machine controller (e.g. PLC), comprises a position
measuring system. It is intended to be installed into a
machine or system and used in the industrial sector.
Flawless function in accordance with the specifications in
the technical data is ensured only when using suitable
original Balluff accessories. Use of any other components
will void the warranty.
Non-approved use is not permitted and will result in the
loss of warranty and liability claims against the
manufacturer.
Reasonably foreseeable misuse
The product is not intended for the following applications
and areas and may not be used there:
–
In safety-oriented applications in which personal safety
depends on the device function
–
In explosive atmospheres
–
In food applications
Mounting surface
0.5 Ø 25
25
10.5
34
1) Unusable area
2) Not included in scope of delivery
1
english
Null point
1)
Measuring length
X
2)
Magnet
Thread size:
BTL B...: M18×1.5
BTL Z...: 3/4"-16UNF
Safety notes
Activities such as installation, connection and
commissioning may only be carried out by qualified
personnel.
Qualified personnel are persons whose technical
training, knowledge and experience as well as knowledge
of the relevant regulations allow them to assess the work
assigned to them, recognize possible hazards and take
appropriate safety measures.
The operator is responsible for ensuring that local safety
regulations are observed.
In particular, the operator must take steps to ensure that a
defect in the product will not result in hazards to persons
or equipment.
The product must not be opened, modified or changed. In
case of defects and unrepairable malfunctions of the
product, it must be taken out of operation and secured
against unauthorized use..
Dimensions and function
To determine the position of a plant component, a magnet
is connected to the component. Together they are moved
along a waveguide located inside the BTL.
End point
1)
60
Rod end
Type
X
BTL _NCA...
30 −1 mm
with thread M4/4.5 deep
BTL _NCE...
2" −0.04"
with thread M4/4.5 deep
BTL _NCC...
30 −1 mm
No thread
BTL _NCG...
2" −0.04"
No thread
BTL _NCJ...
40 −1 mm
with thread M4/4.5 deep
BTL _NCL...
40 −1 mm
No thread
Ø45