NAVIPASS Modbus - Accessory
6. NAVISTEM H3100 (SANIGAZ EVO) EXCHANGE TABLE
6.1
Exchange table
Modbus register
HMI parameter
(Navipass)
H3100
Decimal
Hexa
Navipass Gateway
8
8
--
9
9
--
General boiler room
717
2CD
11
General
100
64
Info button*
Boiler
110
6E
8311
111
6F
8310
113
71
8316
114
72
8005
115
72
8009
116
74
8326
235
EB
8330
236
EC
8331
259
103
8338
260
104
8339
724
2C6
8380
DHW
600
258
561 → 566
191
BF
1610
192
C0
1612
258
102
1640
193
C1
8831
194
C2
8830
1641
710
2C6
1642
711
2C7
1644
712
2C8
1645
713
2C9
1646
714
2CA
196
C4
8003
2CB
715
8820
F9
249
1680
Input configuration
E4
228
5950
E5
229
5951
Diagnostic
2CC
716
9017
82 / 202
Nb
Data
register
1
Modbus parameter (ex : speed)
1
Time out Modbus
3
Time and date
1
Error code
1
Generator starting set-point
1
Generator starting temperature
1
Generator fumes temperature
1
Generator state
1
Burner state
1
Generator modulation
2
No. of hours burner
2
No. of starts burner
No. of hours of operation of the
2
heating
No. of hours of operation of the
2
DHW
2
Global Energy*****
42
DHW program
Temp. set-point Domestic hot
1
water comfort
1
setpoint temp. Reduced DHW
1
Anti-legionalla function
Temp. set-point Current
1
domestic hot water
1
DHW temperature
1
Anti-legionalla cycle period
1
Day week anti-legionella cycle
1
Anti legionella function time
1
Anti legionella cycle period*******
1
Anti legionella cycle period
1
Domestic hot water state
1
DHW pump status
1
Change of DHW mode.
1
H1 input function
1
Contact action H1
1
Special probe T° 2
Access
Possible values
Read. Writ.
0 ... 1227
0 ... 10 000
See explanations
***
0 ... 999
0,0 °C ... 140,0 °C
0,0 °C ... 140,0 °C
0,0 °C ... 350,0 °C
0 ... 255
0 ... 255
0 ... 100 %
0...65535 hours
0...199999
0...199999 hours
0...199999 hours
0...2147483647 kWh 0...2147483647
FFFF, 00:00...23:59
Reduced T° setpoint
DHW ... 80 °C
8°C ... Domestic hot
water comfort set-point
Stop/period/day of the
fixed week
8 °C ... 80 °C
0,0 °C ... 140,0 °C
[1..7 days]
1 : monday
7 : sunday
FFFF,0h00 to 23h50***** -1, 0 to 5958
55 °C ... 95 °C
[1..7 days]
0 ... 255
On / off
Without/off/on
See table AA for
B3000 and AC for
B2000/B2100
Rest contact (0)/
working contact (1)
0,0 °C ... 140,0 °C
Displayed
Data
values
type
See chapter §
u16
See chapter §
u16
u16 by
register
[0..999]
u16
[0..1400]
u16
[0..1400]
u16
[0..3500]
u16
[0..255] **
u8
[0..255] **
u8
[0..100]
u8
00 ... 65535
u32
00...199999
u32
0....199999
u32
0....199999
u32
u32
See end of
u16 by
table
register
[8..80]
u8
[8..80]
u8
0...2
u8
[8..80]
u8
[0..1400]
u16
[1..7]
u8
[1..7]
u8
u16
[550..950]
u16
[1..7]
u8
[0..255] **
u8
[0..1]
u8
0/1/2
u8
0...14/0...58
u8
0...1
u8
[0..1400]
u16
00ANO0019-G_EN