NAVIPASS Modbus - Accessory
Modbus register
HMI parameter
(Navipass)
T3100
Decimal
Hexa
135
87
710
136
88
712
137
89
8741
138
8A
8740
139
8B
8000
237
ED
5710
246
F6
900
Heating circuit 2
722
2D2
Panel key
400
190
521 ... 526
151
97
1020
152
98
1021
153
99
8774
154
9A
8773
155
9B
1010
156
9C
1012
157
9D
8771
158
9E
8770
159
9F
8001
238
EE
5715
247
F7
1200
Heating circuit 3
723
2D3
Panel key
500
1F4
541 ... 546
171
AB
1320
172
AC
1321
173
AD
8803
174
AE
8804
175
AF
1310
88 / 202
Nb
Data
register
Temp. set-point Comfort
1
heating, zone 1
setpoint temp. reduced heating
1
zone 1
Temp. set-point Current thermal
1
comfort, zone 1
1
Ambient temperature, zone 1
1
State, zone 1
On/Off heating circuit 1
1
Activation/déactivation
1
Regime change CC1 via input H
1
CC2 operating mode
42
Zone 2 Heating Program
1
Water law, zone 2
1
Water law offset, zone 2
Calculated starting set-point,
1
zone 2
1
Starting set-point, zone 2
Setpoint temp. reduced heating
1
zone 2
setpoint temp. reduced heating
1
zone 2
Temp. set-point Current thermal
1
comfort, zone 2
1
Ambient temperature, zone 2
1
Zone 2 status
On/Off heating circuit 2
1
Activation/déactivation
1
CC2 mode change via input H
1
CC3 operating mode
42
Heating program, zone 3
1
Water law, zone 3
1
Water law offset, zone 3
1
Calculated starting set-point, zone 3
1
Starting set-point, zone 3
Temp. set-point Comfort
1
heating, zone 3
Access
Possible values
Read. Writ.
Between zone 1
heating T° setpoint
and maximum heating
T° setpoint
Between min heating
T° setpoint and
heating comfort T°
setpoint zone 1
4,0 °C ... 40,0 °C
(by 0,5 °C)
4,0 °C ... 40,0 °C
0 ... 255
On/off
See AD list
1: permanent confort
2 : permanently reduced
3 :automatic
7 : frost protection
FFFF, 00:00...23:59
0,1 ... 4
-4,5 ... 4,5
0,0 °C ... 140,0 °C
0,0 °C ... 140,0 °C
Between Zone 2
heating reduced
T° setpoint and
maximum heating T°
setpoint
Between min heating
T° setpoint and zone
2 heating comfort T°
setpoint
4,0 °C ... 40,0 °C
(par 0,5 °C)
4,0 °C ... 40,0 °C
0 ... 255
On/off
See AD list
1: permanent confort
2 : permanently reduced
3 :automatic
7 : frost protection
FFFF, 00:00...23:59
0,1 ... 4
-4,5 ... 4,5
0,0 °C ... 140,0 °C
0,0 °C ... 140,0 °C
Between Reduced
T° heating setpoint
in zone 3 and max
heating T° setpoint
Displayed
Data
values
type
[70..280] *
u16
[70..280] *
u16
[40..400]
u16
[40..400]
u16
[0..255] **
u8
0...1
u8
0...4
u8
1...3,7
u8
See end of
u16 by
table
register
[1..40]
u8
[-45..45]
s8
[0..1400]
u16
[0..1400]
u16
[70..280] *
u16
[70..280] *
u16
[40..400]
u16
[40..400]
u16
[0..255] **
u8
0...1
u8
0...4
u8
1...3,7
u8
See end of
u16 by
table
register
[1..40]
u8
[-45..45]
s8
[0..1400]
u16
[0..1400]
u16
[70..280] *
u16
00ANO0019-G_EN