7. Do not subject the anchor rod to load during
the curing time t
.
cure
1 7
t
cure
8. When the curing time t
is reached, you
cure
can install the shaft: screw on with a torque
of max. 40 Nm.
1 8
T
inst.
Curing time t
and t
rel
cure
The curing times only apply to a dry anchorage
substrate. If the anchorage substrate is damp,
the curing times must be doubled.
1)
2)
Temp
t
rel
-5 ... -1 °C
60 min
0 ... 9 °C
30 min
10 ...19 °C
20 min
20 ... 40 °C
8 min
1)
Temperature in anchorage substrate
2)
Curing time: The screwed in embedment tools are removed
3)
Curing time: Full load
Information
The safety data sheet for the Hilti HVU anchor
capsule can be viewed online at www.hilti.com.
Appendix: Hilti Foundation Fastening Kit
Cleaning alternatives
Manual cleaning (MC)
Hilti manual blow-out pump for blowing out
drill holes.
3)
t
cure
5 h
1 h
Compressed air cleaning (CAC)
30 min
Blow-out nozzle with a minimum diameter
of 3.5 mm.
20 min
Automatic cleaning (AC)
Cleaning is carried out by the Hilti TE-CD and TE-YD
drilling system with on-board vacuum system while
drilling is in progress. This drilling system removes
drilling dust during the drilling process.