Descargar Imprimir esta página

Allmatic RCOO PLUS Manual De Instalacion Y Uso página 22

Sistema de radio para bordes sensibles de seguridad

Publicidad

Idiomas disponibles

Idiomas disponibles

2. PRODUCT DESCRIPTION
The TCOO-RCOO PLUS system allows radio (wireless) operation to transmit the signal of a sensitive safety edge to the control
unit (CU). The receiver (RCOO) constantly checks the status of the transmitters connected to it (TCOO) and automatically selects
the transmission frequency that guarantees the best communication quality among those available. The receiver sets its output
to alarm state when an obstacle is detected from the sensitive safety edge connected to the transmitter. Up to two TCOO can be
connected to an RCOO. Each RCOO has two outputs that can be connected to the control unit.
2.1 - INTENDED USE
Radio system for connecting sensitive safety edges to control panels for the automation of residential, commercial and industrial
doors and gates.
If the door control panel carries out a diagnostic check of the system prior to each movement, this product allows to realize a pro-
tection system type PL "c" -CAT 2 according to EN ISO 13849-1:2015.
The diagnostic control consists of sending a polarised test command (Vtest) to the receiver and verifying that the output contact is
in the alarm position. After that the test command may be interrupted.
Any installation and use different from what is indicated in the following manual are prohibited.
2.2 - TECHNICAL CHARACTERISTICS
Commercial name
The product complies with the following Directives and
Harmonized Standards
Construction of the device
Purpose of the device
Working frequency (automatically selected)
Supply voltage
Current consumption RCOO
Battery life (TCOO) *
Radiated power
RCOO radio memory
RCOO relay output (OUT1 / OUT2)
Usable sensitive edge types (EDGE1 / EDGE2)
Maximum reaction time for safety edge intervention
Intervallo di diagnostica della comunicazione radio
Maximum distance between devices (in open field)
Environmental operating conditions
Conditions of transport and storage
Degree of environmental protection
6 - English - Translated from the original language
RCOO
CU
TCOO 1
EDGE A
EDGE B
TCOO 2
EDGE C
EDGE D
TCOO PLUS
2014/53/UE RED
Electronic device with independent installation
Safety device EN ISO 13849-1:2015 category 2
Channel 1: 868,100 MHz - Channel 2: 868,300 MHz - Channel 3:
868,500 MHz - Channel 4: 869,500 MHz - Channel 5: 869,900 MHz
2 x 1,5V
(alkaline LR6/AA batteries)
< 70 mA @ 12Vdc
12 ÷ 24 months
MAX 2 TCOO
Resistive edges (8.2 K Ohm)
Mechanical edges (normally closed contact)
TA: -20...+55 °C RH max 90% non-condensing
TA: -40...+70 °C RH max 90% non-condensing
RCOO PLUS
12 ÷ 24 Vac/dc
< 25 mW
MAX 1 A
40 ms
1 s
50 m
IP65
6-1620173M - rev. 0 - 30/10/2023

Publicidad

loading

Productos relacionados para Allmatic RCOO PLUS

Este manual también es adecuado para:

Tcoo plus