Descargar Imprimir esta página

Allmatic RCOO PLUS Manual De Instalacion Y Uso página 24

Sistema de radio para bordes sensibles de seguridad

Publicidad

Idiomas disponibles

Idiomas disponibles

3. RECEIVER "RCOO PLUS"
1
2
3
1.
LED POWER ON
2.
DIP-SWITCH selector for configuration (TAB.1)
3.
Terminal block for connection of the supply voltage
(Valim)
4.
Terminal block for connection of the TEST control (Vtest)
5.
Terminal block for connection of the OUT1 output
6.
Terminal block for connection of the OUT2 output
7.
Output Configuration Selector (TAB.2)
8.
PROG/RESET button
9.
Buzzer for acoustic signals
10. Antenna
TAB.1
DIP SWITCH SELECTOR
1 - TEST POLARITY
2 - RADIO CHECK
3 - BUZZER OFF
TAB.2
POSITION
OUT1
OUT2
8 - English - Translated from the original language
4
OFF
Test control with positive polarization:
TEST not active = OV
TEST active = 12/24vdc
Normal functionality:
verification of the presence of associated TCOO
Enable the acoustic signals
= NC
Consent = closed circuit
Alarm = open circuit
Consent = closed circuit
Alarm = open circuit
5
6
LED
POWER ON
RCOO not powered
No communication
RADIO
from an associated
CHECK
TCOO
OUT1 output in
L1
consensus
OUT2 output in
L2
consensus
RCOO in normal
PROG/RESET
operation mode
Test command with negative polarization:
TEST not active = 12/24vdc
TEST active = 0V
Advanced functionality:
verification of the quality of radio
communication between RCOO and TCOO
Disable the acoustic signals
Consent = 8K2 ohm
Alarm = closed circuit
Consent = 8K2 ohm
Alarm = closed circuit
10
9
8
7
OFF
ON
RCOO properly
powered
No associated TCOO
OUT1 output in
alarm
OUT2 output in
alarm
RCOO in
programming mode
ON
= 8K2
6-1620173M - rev. 0 - 30/10/2023

Publicidad

loading

Productos relacionados para Allmatic RCOO PLUS

Este manual también es adecuado para:

Tcoo plus