PRODUCT INFORMATION
Description
The Franklin Electric Inline 400 Pressure Boosting System provides consistent water pressure boost-
ing in residential and small commercial applications that suffer from low water pressure or demand-
based fluctuating water pressure. When added to the existing water supply, the Inline 400 senses
fluctuating water pressure, and automatically increases pressure throughout the system.
The Inline 400 is equipped with a flow sensor and dual pressure switches. It will turn on when the:
Discharge pressure drops below 40 psi (2.8 bar), or
Flow through the Inline 400 is 0.5 gpm (1.9 lpm) or greater
The Inline 400 system stops boosting pressure when the demand for water drops below the 0.5 gpm
(1.9 lpm) flow rate (pump will turn off around 15 seconds after the flow stops). The unit can also be
manually shut down during normal operation by pressing the pushbutton on the cap.
The Inline 400 is easy to install (mounting either vertically or horizontally) while working with vir-
tually any existing plumbing configuration.
The unit is equipped with two LED lights to provide system status and diagnostic information.
Features
Configuration
Plug-in electrical cord connected unit
Installs vertically or horizontally
Includes pressure tank if ordered as accessory
Maximum Inlet Water Temperature: 120 °F (49 °C)
Operation
Two LED indicators for system status and troubleshooting
Simple flow-based controls boost pressure on demand
Single phase operation
Maximum suction lift of 5 feet (1.5 m)
Protection
Overvoltage (+10% of rated)
Undervoltage (-10% of rated)
Dry Run (i.e. motor is running but no pressure or flow is being developed)
Overheat (greater than 120 °F internal water temperature)
Models
Input
Model
Voltage
Hz HP Amps Watts Phase
(VAC)
115
Inline 400
60
230
6.6
710
1
3.3
Maximum
Maximum
Maximum
Boost
System
psi (bar)
psi (bar)
gpm (lpm)
55 (3.79)
95 (6.55)
20 (75)
PRODUCT INFORMATION
Enclosure
Weight
Flow
Type
lbs (kg)
CSA
35 (16)
Type 3
Description
3