Descargar Imprimir esta página

Franklin Electric INLINE 400 Manual De Instalación Y Operación página 5

Ocultar thumbs Ver también para INLINE 400:

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION
Typical Installation
11
1
7
4
1 Water from source
2 Inline 400
3 Power Cord
4 Ball Valve
Environmental Requirements
Risk of malfunction can occur due to improper handling, installation, or
environment.
Handle with care to prevent damage to the plastic components.
Do not mount on equipment with excessive vibration.
Install in a location where temperature is within the range of product rating.
Do not install in corrosive environments.
1.
Install in a clean, well-ventilated location that provides protection from freezing, flooding, and exces-
sive heat.
2. Provide access for servicing and allow convenient draining of the pump housing, tank, and service
pipes.
3. Install the system away from items that could be damaged by water leaks.
NOTE: Priming and bleeding air from the system can produce wet conditions.
4
3
6
2
10
5 Pressure Tank
6 Pressure Gauge
7 Inlet Pressure Reducing Valve (optional)
8 Outlet Pressure Reducing Valve (optional)
12
5
11
10
8
9 Pressure Relief Valve
10 Union Coupling
11 Pipe Tee
12 Check Valve
INSTALLATION
Typical Installation
11
6
4
9
5

Publicidad

loading