Descargar Imprimir esta página

Ferroli BlueHelix HiTech RRT H Instrucciones De Uso, Instalación Y Mantenimiento página 311

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

BlueHelix HiTech RRT H
Connection to collective flues
C
8X
fig. 37- Examples of connection to collective flues (
Table 9- Typology
Type
Description
C8X
Exhaust in single or common flue and wall intake
B3X
Intake from installation room by means of concentric duct (that encloses the exhaust) and exhaust in common flue with natural
draft
IMPORTANT- THE ROOM MUST BE PROVIDED WITH APPROPRIATE VENTILATION
C93
Exhaust to a vertical terminal and intake from existing flue.
If the BlueHelix HiTech RRT H boiler is to be connected to a flue or a single chimney with natural
draft, the flue or chimney must be expressly designed by professionally qualified technical person-
nel in conformity with the current regulations and be suitable for sealed chamber units equipped
with fan.
Clapet non-return valve
The BlueHelix HiTech RRT H boiler is fitted as standard with a Clapet non-return valve (backflow
preventer) therefore, only if running on Natural Gas, it can be connected to collective flues in
positive pressure.
Using this type of installation, parameter P67 must be set to 1.
In case of a type C(10)3 or C(11)3 boiler installation apply, IN A CLEARLY VISIBLE PLACE
on the FRONT PANEL, the relevant white sticker included in the document envelope sup-
plied with the unit.
After installation, check the tightness of the fumes and gas circuit.
B
EN
C
C
93
cod. 3541V484 - Rev 02 - 01/2024
2X
C
93
= Air /
C
4X
= Fumes)
311

Publicidad

loading