View this manual online at www.lbwhite.com
Attention
The Sentry heater has been
designed, tested, and evaluated by
the L.B. White Company as a direct
gas fired radiant tube heater. The
heater is designed specifically for
the intended use of heating animal
confinement buildings only.
CHECK WITH YOUR LOCAL
FIRE SAFETY AUTHORITY,
YOUR LOCAL FUEL GAS
SUPPLIER, OR THE L.B.
WHITE COMPANY IF YOU
HAVE QUESTIONS
REGARDING APPLICATIONS.
www.lbwhite.com
SEE ASSEMBLY
INSTRUCTIONS
INSIDE
Please refer to important
elevation information on
inside cover.
WORLD PROVIDER - INNOVATIVE HEATING SOLUTIONS
411 Mason Street, Onalaska, WI 54650 • 800-345-7200 • 608-783-5691 • 608-783-6115 (fax) • www.lbwhite.com
Owner's Manual and Instructions
Sentry
Single and Two Stage
Radiant Tube Heaters
ST60/ST80
Congratulations!
You have purchased the finest agricultural building heater available.
Your new L.B. White heater incorporates the benefits from the most experienced
manufacturer of heating products using state-of-the-art technology.
We, at L.B. White, thank you for your confidence in our products and welcome
any suggestions or comments you may have...contact us at 1-(800)-345-7200,
or email us at customerservice@lbwhite.com.
The herein installation instructions are the L.B. White Co. LLC
suggested recommendations and guidelines for temporary or
permanent installation of the L.B. White Co. LLC heaters. Local,
state, and electrical and safety code requirements supersede these
guidelines. In the absence of local codes, see page 7 for installa-
tion in the U.S. or Canada.
ST60*
ST80*
ST100
ST125
Propane Vapor Withdrawal or Natural Gas
*Single Stage only
NOTICE
SCAN THIS
with your smartphone or
visit http://goo.gl/yyKxJo to
view maintenance videos
for L.B.White heaters.
* Requires an app like QR Droid
for Android or for iPhone
60,000 Btuh
80,000 Btuh
100,000 Btuh
125,000 Btuh
ST100/ST125

Publicidad

loading

Resumen de contenidos para L.B.White Sentry ST80

  • Página 1 SCAN THIS INSTRUCTIONS with your smartphone or visit http://goo.gl/yyKxJo to INSIDE view maintenance videos for L.B.White heaters. Please refer to important * Requires an app like QR Droid elevation information on for Android or for iPhone inside cover. WORLD PROVIDER - INNOVATIVE HEATING SOLUTIONS...
  • Página 2 Sentry Tube Heaters TABLE OF CONTENTS Heater Specifications ......................4 General Information ......................5 Safe Clearance From Combustibles ................5 Safety Precautions ......................6 Inlet Air Requirements ....................9 General Installation Instructions ...................10 Start-Up Instructions .....................17 Shut-Down Instructions ....................17 Cleaning Instructions ....................18 Maintenance Instructions ....................19 General Service Instructions ..................19 Troubleshooting Information ..................26 Electrical Connection and Ladder Diagram ..............30...
  • Página 3 Sentry Tube Heaters GENERAL HAZARD WARNING ■ FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER CAN RESULT IN: — DEATH — SERIOUS BODILY INJURY OR BURNS — PROPERTY DAMAGE OR LOSS FROM FIRE OR EXPLOSION — ASPHYXIATION DUE TO LACK OF ADEQUATE AIR SUPPLY OR CARBON MONOXIDE POISONING —...
  • Página 4 Sentry Tube Heaters Specifications ST60 ST80 ST100 ST125 Available Tube Lengths (ft.) Maximum Input per Hour BTU/H 60,000 80,000 100,000 125,000 Minimum Input per Hour (Two Stage) 65,000 75,000 Fuel Consumption per Hour (Max.) LPG (lbs.) 4.63 5.79 NG (cu. ft.) Gas supply pressure acceptacle for the 13.5 / 11.0 MAX./...
  • Página 5 Sentry Tube Heaters General Information This owner’s manual includes all options and ac- expert training and knowledge of gas heaters and cessories commonly used on or with this heater. should not be attempted by anyone who is not so However, depending on the configuration purchased, qualified.
  • Página 6 Sentry Tube Heaters Safety Precautions WARNING Asphyxiation Hazard ■ Do not use this radiant heater for heating human living quarters. ■ Do not use in unventilated areas. ■ The flow of combustion and ventilation air must not be obstructed. ■ Proper ventilation air must be provided to support the combustion air requirements of the heater being used.
  • Página 7 Sentry Tube Heaters Attention - Critical Points to Remember! 2. All installations and applications of L.B. White heat- ■ Propane gas and natural gas have a distinctive odor. Learn to recognize these odors. (Reference ers must meet all relevant local, state and national “Fuel Gas Odor”...
  • Página 8 Sentry Tube Heaters 9. The hose assembly shall be visually inspected on an annual basis. If it is evident there is excessive abrasion or wear, or if the hose is cut, it must be replaced prior to the heater being put into opera- tion.
  • Página 9 90º bend is allowed. -- Refer to Inlet Air Requirements instructions. -- Contact L.B.White Co. if you have any questions ■ Failure to provide a fresh air inlet can lead to: regarding the installation of the heater.
  • Página 10 Sentry Tube Heaters FIG. 4 DRAWING INLET AIR THROUGH SIDEWALLS Use minimum length of 4 in. diameter flex duct when connecting 4 in. PVC to burner box. An adapter connection for the burner box to the 6 in. PVC must be obtained through local source.
  • Página 11 Sentry Tube Heaters -- Regulators mounted outside must be protected further tightening. from adverse weather conditions. -- Tighten the gas connection as necessary to stop the -- Regulators with pressure relief valves should be leak. installed outside the building. -- If necessary, replace the parts or components involved -- Regulators installed inside should be vented if the leak cannot be stopped.
  • Página 12 BURNER DISCHARGE Sentry Tube Heaters FIG. 6 17. Any defects found in performing any of the service FIG. 6 procedures must be eliminated and defective parts BURNER BOX BURNER BOX HANGING CHAINS HANGING CHA replaced immediately. Retest the heater before placing it back into service.
  • Página 13 Sentry Tube Heaters 3. Slide on hangers and connect to chains. 4. Connect and hang remaining tubes. Follow the procedures given in Step 2. 5. The tube assembly should be either hung level, or with a downward slope away from the burner box not exceeding 1 in.
  • Página 14 Sentry Tube Heaters Installing Reflectors & Supports Refer to Fig. 8 for the following instructions: 4. Repeat Steps 3 for remaining reflectors. 1. Attach end cap to one end of the first reflector. Use 5. Install a support hanger at the end of the reflector the 4 U-clips to secure it to the relector.
  • Página 15 Sentry Tube Heaters Air Turbulation Strips Sediment Trap Assembly & Vent Assemble the tee, nipple, and cap to the nipple at the gas inlet of heater. See Fig. 10. Use a wrench to hold the pipe nipple when installing the sediment trap. When installing the air turbulators, make Tighten securely.
  • Página 16 Sentry Tube Heaters Temperature Sensor Location 5 FT. FROM CENTER OF TUBE TO SENSOR LOCATION SENSOR LOCATED ABOVE SIDEWALL ANIMAL HEIGHT FLOOR SENSOR LOCATION FROM BURNER BOX 10 FT. SENSOR LOCATED ABOVE ANIMAL HEIGHT FLOOR Heater Controls Heaters with Two Stage Gas Control Valves WARNING Heaters with two stage gas controls are wired to start up Electrical Shock Hazard...
  • Página 17 Sentry Tube Heaters TRANSFORMER GREEN YELLOW YELLOW BLUE WIRE NUT BLACK GREEN WHITE WIRE NUT YELLOW TO TERMINAL "W" ON IGNITION CONTROL WIRE NUT TO GAS CONTROL VALVE TO HIGH HEAT L.E.D. 2. Building Controller Connections - Remove wire nut at orange, yellow and red wires - Connect controller contacts as shown.
  • Página 18 Sentry Tube Heaters FIG. 13 Start-Up Instructions Follow steps 1 - 6 on initial start-up after heater installation. For normal start-up, set building control RED FAULT LIGHT thermostat above room temperature. The heater will start. GREEN ON GREEN HIGH HEAT 1.
  • Página 19 Sentry Tube Heaters Cleaning Instructions WARNING This heater may be washed only on its external WARNING areas provided: Fire, Burn and Explosion Hazard ■ The burner box is disconnected from the ■ This heater contains electrical and mechanical electrical supply. components in the gas management, safety and ■...
  • Página 20 Sentry Tube Heaters Maintenance Instructions 3. Regulators can wear out and function improperly. Have your gas supplier check the date codes on all regulators installed and check delivery pressures Before Each Use: to the appliance to make sure that the regulator is suitable for continued use.
  • Página 21 Sentry Tube Heaters Igniter FIG. 15 (ST60/ST80) BURNER VANES The tip of the igniter is exposed to a harsh environment consisting of high temperatures and combustion products. Periodic servicing is required. A. REPLACEMENT ST60/ST80 1. Remove igniter mounting screws. See Fig. 14. 2.
  • Página 22 Sentry Tube Heaters Motor and Fan Assembly Air Differential Pressure (ST60/ST80 shown) Switch, Tubing and Orifices. A. Motor/Fan wheel removal. 1. Disconnect motor leads. 2. Remove motor mount screws. See Fig. 17 (ST60/ST80 shown) 3. Remove motor/fan wheel assembly from the burner box.
  • Página 23 Sentry Tube Heaters Air differential switch: FIG. 22 The air differential switch is a normally open, critical safety device. See Fig. 21 for location. Its purpose is GREEN to prove to the ignition control that there is a sufficient BLUE difference in pressure within the burner box before the ignition control sends power to open the gas control valve.
  • Página 24 Sentry Tube Heaters 4. Pull the gas valve assembly through the gas valve Ignition Control door opening. See Fig. 25. The control sends and receives voltages to operate or FIG. 25 verify operation of components. Refer to the following and Fig. 27 to understand the ignition control’s termi- nal designators if doing voltage checks on the control.
  • Página 25 Sentry Tube Heaters Gas Pressure Checks 4. Remove either the inlet or outlet pressure tap. See Fig. 29. (Single stage valve shown) FIG. 29 OUTLET INLET PRESSURE PRESSURE TAP ■ The following is a typical procedure to be followed in checking gas pressures. ■...
  • Página 26 Sentry Tube Heaters specified on the dataplate? If so, then no further checking or adjustment is required. Proceed to section C. 3. If the inlet pressures do not agree with that speci- fied on the dataplate, then the regulator controlling gas pressure to the heater requires adjustment.
  • Página 27 Sentry Tube Heaters Troubleshooting A flashing light indicates a problem. The flash pattern will be followed by a pause and then a Information repeat of the flash pattern until the problem is corrected. Refer to the tables below to identify what page to refer READ THIS ENTIRE SECTION BEFORE to when troubleshooting any problems.
  • Página 28 Sentry Tube Heaters Owner’s Manual • Sentry...
  • Página 29 Sentry Tube Heaters Owner’s Manual • Sentry...
  • Página 30 Sentry Tube Heaters Owner’s Manual • Sentry...
  • Página 31 Sentry Tube Heaters Electrical Connection and Ladder Diagram ST60/80 Owner’s Manual • Sentry...
  • Página 32 Sentry Tube Heaters Electrical Connection and Ladder Diagram ST100/ST125 Owner’s Manual • Sentry...
  • Página 33 Sentry Tube Heaters Service Parts Identification Schematic - Tube/Reflector Owner’s Manual • Sentry...
  • Página 34 Sentry Tube Heaters Parts List - Tube/Reflector Item Description Part # Air turbulation strip 572892 Vent cap, AT 573970 Tube, calorized, 4 in. x 10 ft., with clamp 573010 Tube, stainless steel, 4 in. x 10 ft. w/clamp 573387 Clamp, 4 in. round, SS 574225 Hanger, 4 in.
  • Página 35 Sentry Tube Heaters Service Parts Identification Schematic - Burner Box ST60/ST80 Shown Owner’s Manual • Sentry...
  • Página 36 Sentry Tube Heaters Parts List - Burner Box Item Description ST60/ST80 ST100/ST125 Latches and strike 573775 Red LED 573769 Green LED 573770 Green LED** High Heat 2-Stage only 574159 Wire harness kit 574283 574219 Ignitor with bracket 500-24972 574220 Ignition cable 572847 Tube, air differential pressure switch 572883...
  • Página 37 Sentry Tube Heaters Manual Rev./Changes Date Rev. Revision Change Description 3/15/2018 Released 8/22/2019 Updated the exhaust end cap and reduce gas hose to 3/8” 2/18/2020 Removed 45 degree installation instruction 7/2/2021 Add ST100/125 models to OM 8/2/2021 Updated 2-stage gas valve service number 1/11/2023 Single stage NG manifold pressure was 4.0 Owner’s Manual •...
  • Página 38 If a product has not been limitation or exclusion may not apply to you. This warranty registered with L.B.White, a copy of the bill of sale gives you specific legal rights, and you may also have other will be required to establish warranty qualification.
  • Página 39 EN EL INTERIOR http://goo.gl/yyKxJo para para ver videos de mantenimiento de los Consulte la información im- calefactores L.B.White. portante sobre elevación en la * Necesita una aplicación como QR portada interna. Droid para Android o para iPhone PROVEEDOR MUNDIAL;...
  • Página 40 Calefactores de tubo radiante Sentry ÍNDICE Especificaciones del calefactor ..................4 Información general ......................5 Distancia de seguridad desde los combustibles .............5 Precauciones de seguridad ....................6 Requisitos de entrada de aire ..................9 Instrucciones generales de instalación .................10 Instrucciones de puesta en marcha ................17 Instrucciones de apagado ....................17 Instrucciones de limpieza .....................18 Instrucciones de mantenimiento ...................19...
  • Página 41 Calefactores de tubo radiante Sentry ADVERTENCIA GENERAL ■ SI NO SE CONTEMPLAN LAS PRECAUCIONES E INSTRUCCIONES SUMINISTRADAS CON ESTE CALEFACTOR, PUEDE OCURRIR LO SIGUIENTE: — LA MUERTE — QUEMADURAS O LESIONES GRAVES — DAÑOS O PÉRDIDAS MATERIALES POR INCENDIO O EXPLOSIÓN —...
  • Página 42 Calefactores de tubo radiante Sentry Especificaciones ST60 ST80 ST100 ST125 Longitudes disponibles de tubos (pies) Entrada máxima por hora BTU/H 60,000 80,000 100,000 125,000 Entrada mínima por hora (dos etapas) 65,000 75,000 Consumo de combustible por hora (máx.) GPL (lb) 4.63 5.79 GN (pies cúbicos)
  • Página 43 Calefactores de tubo radiante Sentry Información general Este manual del usuario incluye todas las opciones La instalación de la línea de suministro de gas y la y accesorios que se utilizan regularmente en o con reparación, la instalación y el mantenimiento del este calefactor.
  • Página 44 Calefactores de tubo radiante Sentry Precauciones de seguridad ADVERTENCIA Peligro de asfixia ■ No use este calefactor radiante para dar calor en lugares donde vivan seres humanos. ■ No lo use en áreas sin ventilación. ■ El flujo de aire de ventilación y combustión no debe obstruirse. ■...
  • Página 45 Calefactores de tubo radiante Sentry ¡Atención - Puntos críti- cos que debe recordar! b. Para ser una persona calificada en hacer instalaciones de gas, usted debe tener suficiente ■ El gas propano y el gas natural tienen un olor característico. Aprenda a reconocer estos olores. capacitación y experiencia para manejar todos (Consulte las secciones previas “Olor a gas los aspectos de la instalación, reparación y...
  • Página 46 Calefactores de tubo radiante Sentry 13. Este calefactor está equipado con un enchufe 6. Por seguridad, este calefactor está equipado de tres clavijas (conexión a tierra) para brindar con un interruptor de presión de aire diferencial. protección contra el riesgo de descargas Nunca haga funcionar el calefactor si algún eléctricas, y se debe conectar directamente a un dispositivo de seguridad se ha desactivado.
  • Página 47 -- Consulte las instrucciones de los requisitos de se permiten curvas de más de 1 a 90º. la entrada de aire. -- Comuníquese con L.B.White Co. si tiene ■ La falta de una entrada de aire fresco puede preguntas sobre la instalación de este calefactor.
  • Página 48 Calefactores de tubo radiante Sentry ASPIRACIÓN DEL AIRE DE ENTRADA DESDE FIG. 4 LAS PAREDES LATERALES Use un tramo de tubo flexible de un largo mínimo de 4 in cuando conecte el tubo de PVC de 4 in a la caja del quemador.
  • Página 49 Calefactores de tubo radiante Sentry -- Los reguladores instalados en el interior deben -- Ajuste la conexión de gas según sea necesario para ventilarse hacia el exterior. detener la fuga. -- Si fuera necesario, reemplace las piezas o compo- -- Se aplican los códigos locales, estatales y nentes pertinentes si no puede detenerse la fuga.
  • Página 50 BURNER DISCHARGE Calefactores de tubo radiante Sentry FIG. 6 17. Cualquier defecto que halle en la realización de FIG. 6. alguno de los procedimientos de mantenimiento CAJA DEL QUEMADOR CADENAS DE BURNER BOX BURNER BOX HANGING CHAINS HANGING CHA SUSPENSIÓN debe eliminarse y las partes defectuosas deben reemplazarse de inmediato.
  • Página 51 Calefactores de tubo radiante Sentry 3. Deslice los soportes y conecte a las cadenas. 4. Conecte y cuelgue los tubos restantes. Siga los procedimientos especificados en el paso 2. 5. El conjunto del tubo debe estar al nivel de colgado o con una inclinación hacia abajo, lejos del quemador, que no supere 1 pulgada por cada 10 pies de tubo.
  • Página 52 Calefactores de tubo radiante Sentry Instalación de reflectores y soportes Consulte la FIG. 8 para las siguientes instrucciones: 4. Repita los pasos 3 para los demás reflectores. 1. Coloque la tapa del extremo en un extremo del primer 5. Instale una percha de soporte en el extremo del reflector.
  • Página 53 Calefactores de tubo radiante Sentry Tiras de turbulencia Conjunto del colector de de aire y ventilación sedimentos Monte la T, el niple y la tuerca en el niple en la Ensamble las tiras e insertarlas en el entrada de gas del calefactor. Consulte la Fig. 10. Use último tubo (vea la Fig.
  • Página 54 Calefactores de tubo radiante Sentry Ubicación del sensor de temperatura 5 PIES DESDE EL CENTRO DEL TUBO HASTA LA UBICACIÓN DEL SENSOR SENSOR LOCALIZADO SOBRE LA ALTURA ANIMAL EL PISO UBICACIÓN DEL SENSOR DESDE LA CAJA DE QUEMADORES 10 PIES SENSOR LOCALIZADO SOBRE LA ALTURA ANIMAL EL PISO...
  • Página 55 Calefactores de tubo radiante Sentry TRANSFORMADOR VERDE AMARILLO AMARILLO AZUL TUERCA DE TERMINAL NEGRO ROJO VERDE ALTO BAJA BLANCO TUERCA DE TERMINAL AMARILLO AL TERMINAL "W" SOBRE CONTROL DE ENCENDIDO ROJO TUERCA DE TERMINAL ROJO A LA VÁLVULA DE CONTROL DE GAS ROJO AL CALOR ALTO L.E.D.
  • Página 56 Calefactores de tubo radiante Sentry Instrucciones de puesta 4. En una llamada de calor, el motor arrancará y funcionará durante en marcha 5. Segundos y la luz verde ON se encenderá. losLa Para el encendido inicial, siga los pasos 1 a 6 luz verde High Heat se encenderá...
  • Página 57 Calefactores de tubo radiante Sentry c. Cuando lave con agua, no rocíe agua en la ADVERTENCIA caja del quemador ni los tubos. Lea y obedezca Peligro de incendio, quemaduras y las advertencias que se incluyen en estas explosión Instrucciones de limpieza. La misma advertencia ■...
  • Página 58 Calefactores de tubo radiante Sentry Instrucciones de 3. Los reguladores se pueden desgastar y pueden no funcionar adecuadamente. Pida a su proveedor de mantenimiento gas que verifique los códigos de fecha que figuran en todos los reguladores instalados y las presiones Antes de cada uso: que llegan al aparato para asegurarse de que el regulador sea adecuado para un uso continuo.
  • Página 59 Calefactores de tubo radiante Sentry FIG. 15. (ST060/ST080) Encendedor ASPAS DEL QUEMADOR La punta del encendedor está expuesta a un arduo ambiente con altas temperaturas y productos de combustión. Se requiere el mantenimiento periódico. A. REEMPLAZO ST60/ST80 1. Extraiga los tornillos de montaje del encendedor. Consulte la Fig.
  • Página 60 Calefactores de tubo radiante Sentry Conjunto del motor Interruptor de presión de y el ventilador aire diferencial, tubos y orificios. (ST60/ST80 mostrado) A. Extracción del conjunto de motor y turbina (ST60/ST80 mostrado) 1. Desconecte los cables del motor. Tubo del interruptor de presión: 2.
  • Página 61 Calefactores de tubo radiante Sentry deben estar limpios. Si es necesario limpiarlos, use Interruptor de diferencial de aire: El interruptor del diferencial de aire es un dispositivo aire presurizado: de seguridad crítico, comúnmente abierto. Consulte • Quite el orificio correspondiente del interruptor. la Fig.
  • Página 62 Calefactores de tubo radiante Sentry Transformador Válvula de control de gas El transformador (Fig. 26) reduce el voltaje de (ST60/ST80 mostrado) suministro de energía principal a 24 V de CA. El voltaje 1. Quite la manguera de la trampa de sedimentos. 24 V de CA se envía directamente al controlador de encendido.
  • Página 63 35 pulg. de columna de de aire. agua (también se puede pedira a W: 24 V de CA del transformador al control. (sin este L.B.White, número de pieza 00764) voltaje, el control de encendido no funcionará) Buje, 1/2.x1/8 pulgadas. FS: sin terminal.
  • Página 64 Calefactores de tubo radiante Sentry 4. Si la presión de entrada es correcta, pero la presión 3. Abra el panel de acceso a la caja del quemador. del colector del quemador no concuerda con la que se especifica en la placa de datos, entonces se 4.
  • Página 65 Calefactores de tubo radiante Sentry Un destello de luz indica un problema. Información de El patrón de parpadeo será seguido de una pausa y luego resolución de problemas la repetición del patrón de destellos, hasta que se corrija el problema. En las tablas siguientes, verá qué página debe LEA TODA ESTA SECCIÓN ANTES DE COMENZAR A consultar para la resolución de problemas.
  • Página 66 Calefactores de tubo radiante Sentry Manual del usuario • Sentry...
  • Página 67 Calefactores de tubo radiante Sentry Manual del usuario • Sentry...
  • Página 68 Calefactores de tubo radiante Sentry Manual del usuario • Sentry...
  • Página 69 Calefactores de tubo radiante Sentry Conexión eléctrica y diagrama de escalera ST60/80 Manual del usuario • Sentry...
  • Página 70 Calefactores de tubo radiante Sentry Conexión eléctrica y diagrama de escalera ST100/ST125 Manual del usuario • Sentry...
  • Página 71 Calefactores de tubo radiante Sentry Esquema de identificación de piezas de servicio: tubos y reflector Manual del usuario • Sentry...
  • Página 72 Calefactores de tubo radiante Sentry Lista de peizas - Tubo/Reflector Descripción Número Ítem de pieza Tira de turbulencia de aire 572892 Tapa de ventilación, AT 573970 Tubo, cal’orica, de 4 in x 10 ft, con abrazadera 573010 Tubo, acero inoxidable, 4 pulgadas x 10 pies, con abrazadera 573387 Abrazadera, redondo de 4 pulgadas 574225...
  • Página 73 Calefactores de tubo radiante Sentry Esquema de identificación de piezas de servicio - Caja de quemador ST60/ST80 Mostrado Manual del usuario • Sentry...
  • Página 74 Calefactores de tubo radiante Sentry Lista de piezas - Caja de quemador Número Descripción de pieza Ítem Pestillos y golpe 573775 Luz LED roja 573769 Luz LED verde 573770 LED verde ** Solo 2 etapas de alta temperatura 574159 Mazo de cables 574283 574219 Encendedor con soporte...
  • Página 75 Política de garantía CALEFACTOR o emergentes directa o indirectamente en relación con L.B. White Company, LLC garantiza que las piezas la venta, la manipulación o el uso del equipo. En todo de su calefactor estarán libres de defectos en los caso, la responsabilidad de L.B.

Este manual también es adecuado para:

Sentry st60Sentry st100Sentry st125