Temperature Sensor Location; Heater Controls - L.B.White Sentry ST80 Manual Del Usuario E Instrucciones

Soltera y dos etapa calentadores de tubo radiante
Ocultar thumbs Ver también para Sentry ST80:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

16
Sentry Tube Heaters

Temperature Sensor Location

SIDEWALL
SENSOR LOCATION FROM
BURNER BOX

Heater Controls

WARNING
Electrical Shock Hazard
■ Disconnect the heater's electrical supply before
interconnecting the temperature control.
■ Failure to disconnect the electrical supply will
result in electrical shock.
■ Electrical shock will cause severe injury or
death.
The Sentry heater is operated by the building's environ-
mental control system. To accomplish this, the heater
must be connected to an electrical outlet controlled by
a relay or set of contacts that is closed and opened by
the building controller.
Connecting series tap thermostat kit.
• Connect power cord of heater to female side of
thermostat cord set.
• Plug the male side of cord set into an approved exten-
sion cord or to wall outlet.
Owner's Manual • Sentry
5 FT. FROM CENTER OF TUBE
TO SENSOR LOCATION
SENSOR LOCATED ABOVE
FLOOR
10 FT.
FLOOR
Heaters with Two Stage Gas Control Valves
Heaters with two stage gas controls are wired to start up
and operate in the first stage position as shipped from the
factory. Connections to a thermostat or building controller is
required for further operation.
1. Wiring Two Stage Thermostat
- Remove wire nut at orange and yellow wires.
- Connect wiring of two stage thermostat as shown.
ANIMAL HEIGHT
SENSOR LOCATED ABOVE
ANIMAL HEIGHT

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Sentry st60Sentry st100Sentry st125

Tabla de contenido