OPERATION INSTRUCTIONS
Attempt to use the air conditioner under the temperature beyond the specified range may cause
the air conditioner protection device to start and the air conditioner may fail to operate. Therefore,
try to use the air conditioner in the following temperature conditions.
Inverter air conditioner:
MODE
Temperature
Room temperature
Outdoor temperature
With the power supply connected, restart the air conditioner after shutdown, or switch it to other
mode during operation, and the air conditioner protection device will start. The compressor will
resume operation after 3 minutes.
Characteristics of heating operation (applicable to Heating pump)
Preheating:
When the heating function is enabled, the indoor unit will take 2~5 minutes for preheating, after
that the air conditioner will start heating and blows warm air. The Anti-cold indicator is lighting
during this period.
Defrosting:
During heating, when the outdoor unit frosted, the air conditioner will enable the automatic
defrosting function to improve the heating effect. During defrosting, the indoor and outdoor fans
stop running. The air conditioner will resume heating automatically after defrosting finish.
The Anti-cold indicator is lighting during this period.
Air flow control:
Open the panel and switch the DIP as you like to activate or deactivate the airflow from the bottom
outlet.
Air flow from the outlet on the top and bottom(heating mode)
Air flow only from the outlet on the top(heating mode)
Heating
0
~30
-20
~30
6
Cooling
17
~
32
-15 ~53
Dry