INDOOR UNIT INSTALLATION
Step5: Connect Drainage Hose
5.1 Connect the drainage hose to the drainage port, ensure the joint is firm and the sealing
effect is good.
5.2 Wrap the joint firmly with teflon tape to ensure no leaks.
Note: Make sure there is no twists or dents, and the pipes should be placed obliquely
downward to avoid blockage, to ensure proper drainage.
Step6: Connect Wiring
6.1 Choose the right cables size determined by the maximum operating current on the nameplate.
(Check the cables size refer to section INSTALLATION PRECAUTIONS)
6.2 Open the electric control box cover, to reveal the terminal block.
6.3 Unscrew the cable clamp.
6.4 Connect the wires to corresponding terminal
according to the wiring diagram on the electric
control box cover. And make sure that they are
well connected.
6.5 Screw the cable clamp to fasten the cables.
6.6 Reinstall the electric control box cover.
Drainage horse
Teflon tape
19