Installation Instructions for Gas Conversion
ADJUST BURNER FLAMES
Normally, burners do not need further adjustment.
Make adjustments only when necessary.
A. Turn on the gas. Plug in electrical cord.
B. Turn all burners on highest setting and check
the flames. They should be blue in color. When
using LP gas, the flames may have some yellow
tipping at the ends of the flame. Foreign particles
in the gas line may cause an orange flame at first,
but this will soon disappear.
C. Turn the burner knob to "LO" while observing the
flame.
Adjust the setting of the upper row of flames using
the valve bypass screw as follows:
Adjustments must be made with two other burners
in operation on a medium setting. This prevents the
upper row of flames from being set too low, resulting
in the flame being extinguished when other burners
are turned on.
D. To adjust the flame, remove the knobs. Insert a small
flat-blade screwdriver into the hole in the center of
the valve stem to engage screw.
e If the flames are too small or flutter,
turn the screw counterclockwise.
e If the flames are too large, turn the screw
clockwise.
E. Make the adjustment by slowly turning the screw
until flame appearance is correct.
BURNER OUTPUT RATINGS: BTU/HR
NG (Natural) Gas, 5" W.C.P.
LP (Propane) Gas, 10" W.C.P.
MODEL
BURNER
BTU | ORIFICE SIZE
ID
RATE
MODEL
BURNER
BTU | ORIFICE SIZE
ID
RATE
ZGP48 | ALLSURF.
Main
16,800}
0.075" (1.90mm) | 190XN
ZGP36 | BURNERS
Simmer | 1,200] 0.002" (0.51mm) | 51SL
ZGP48 | ALLSURF.
Main
13,800]
0.043" (1.08mm]) |
108XL
ZGP36 | BURNERS
Simmer | 1,200] 0.013" (0.34mm)} 34SL
Main
16,800}
0.075" (1.90mm) | 190XN
ZGP304 | RF BURNER
Simmer | 1,200]
0.002" (0.51mm) | 51SN
Main
13,800]
0.043" (1.08mm]) | 108XL
ZGP304 | RF BURNER
Simmer | 1,200]
0.013" (0.34mm) ]
34SL
Main
8,800] 0.050" (1.26mm)
|126HXN
ZGP304 | RR, LR, LF gi
simmer | 4 200] 0.002" (0.51mm) | 51SN
Main
7,900] 0.033" (0.84mm]) | 84XL
ZGP304]RR,LR,LF oc
simmer | 4 290] 0.013" (0.34mm) | 34SL
ALL
GRILL
15,000}
0.0689" [1.75mm} | 0.069
ALL
GRILL
14,000]
0.047" (1.19mm]) |
0.047
ALL
GRIDDLE
18,000}
0.076" (1.93mm) | 0.076
ALL
GRIDDLE
16,000]
0.047" (1.19mm]) |
0.047
ZGP48/ | BAKE MAIN
0.0886"
ZGP48/ | BAKE MAIN
0.0571"
ZGP36
24,900
(2.25mm)
0.089
ZGP36
25,000
(1.35mm)
0.09
ZGP30 | BAKE MAIN
23,500]
0.0866" (2.20mm) | 0.087
ZGP30 | BAKE MAIN
21,500]
0.0531" [1.35mm) | 0.053
ZGP48 | BAKE COMPANION =| 10,500]
0.0531" (1.35mm)} |
0.053
ZGP48 | BAKE COMPANION =| 10,000]
0.0374" (0.95mm) | 0.037
ALL
BROIL MAIN
12,500 | 0.063" (1.60mm) |
160
ALL
BROIL MAIN
11,500 | 0.041" (1.04mm) |
104
ZGP48 | BROILCOMPANION |
9,000] 0.052" (132mm) ]
132
ZGP48 | BROIL COMPANION |
9,000} 0.0360" (0.91mm)
91
Once the conversion is complete and checked, fill out the conversion label and affix the label near the rating label. For ranges,
place the label beneath the control panel. For rangetops, place the label on the bottom of the unit.