MAINTENANCE
NOTE: This pump is designed for minimum maintenance. The motor bearings
are self-lubricating. Inspect the pump and components regularly for fuel leaks
and make sure the hose and power cord are in good condition. If damaged,
replace before use. Keep the pump exterior clean to help identify leaks.
IMPORTANT: Do not use this pump for water, chemicals or herbicides.
Dispensing any fluid other than those listed in the owner's manual may damage
the pump (see BEFORE YOU BEGIN: Fueling Compatibility Statement at front
of the owner's manual). Use of the pump with unauthorized fluids will void the
warranty.
Clean or Replace Strainer
1.
Turn the pump off and disconnect from power. Remove the strainer
coverplate, making sure not to damage the O-ring (see Figure 14). Remove
the inlet strainer and inspect for damage or clogs (see Figure 12). Clean the
strainer with a soft-bristled brush and solvent (see Figure 13). If the strainer
is very dirty, compressed air may be used. If damaged, replace the strainer.
2.
Place the strainer in the cavity. Clean the coverplate and O-ring. Coat the
O-ring lightly with grease. Ensure the coverplate O-ring is properly seated
(see Figure 14) and tighten the strainer coverplate.
Figure 12
Figure 14
12
EN
Figure 13