Maintenance
Electronics
Steady red light on the controller box indicates run error. Restart system to troubleshoot errors. If problem recurs, system will switch to safe
mode and red light remains constant.
Conduct yearly system check to prevent drifting of the sensor.
Spiral/Electric Wire
Inspect electric wires daily. Make sure all electric wires are free of rust, dirt, water, oil, and any damage to insulation or plug. Replace spiral
wire yearly.
Wire Rope
Do not yard wire rope more than 10 degrees from vertical center of wire rope guide. Excessive yarding will cause increased wear on the
ZG balancer and decrease the life of the components. Replace wire rope if frayed, kinked, or bird caging is visible.
Refer to the Product Maintenance Manual.