Note: Max weight must not exceed 80% of the ZG balancer capacity.
4. Load is moving up and down but sometimes it's a jerky motion or not working or a red light is blinking in the Control Box.
• This will occur when the operator is moving the load in the handle mode up and down in faster rate.
• This will cause the ADC value in load cell reaching more than Max weight. Hence a red light will blink not allowing the system to go up.
• This is a concept intentionality included in the system to avoid incorrect usage of the ZG balancer.
• In such case, get the load down, turn OFF the system for 10 seconds and turn ON/press the green button. Then operate the handle gently.
5. Load is on the ground but the handle is not moving further down.
• This is an indication of interlock or load balancing.
• In such case, connect the control box to system and open GUI tool.
• If any value is displayed on the last interlock weight or last no load balancing weight, clear it by ticking the box and press on "Write settings"
to update in system.