Make sure to enter the load value in the controller less than 80% of the ZG balancer capacity. Else, the controller will reject the request. During
lifting operation, the controller allows the weight of the load to exceed the set limit by approximately 5 kg.
If the controller reads a weight more than the set maximum weight then upward movement is stopped and red light flashes rapidly. During
this stage, only downward movement is allowed.
Speed Settings
Speed settings are calibrated in factory for different weight ranges and different ZG balancer capacities. The default factory setting is set to
medium speed. A different speed setting can be programmed separately for lowering and lifting by selecting Low/Medium/High from the
respective drop down boxes. Save the settings by clicking on the "Write settings" button.
Sensitivity Control Settings
Sensitivity Control settings are related to float mode operation only. Effort required to move the load by directly applying force on the load is
more when the sensitivity number is high and vice-versa.
Interlock Wiring
The interlock activates an available output on the I/O plug at the back of the handle.
Connect the handling device to the
controller
as follow:
- Pin J and K: Clamp control actuator.
- Pin J and L: Release control actuator.
- Pin J and M: Ready to release information.
EN-6
47804819_ed3