chEcKiNg thE FlamE FailuRE DEvicE
Press the flame failure device button to its stop.
1
2
Light the burner and wait for 15–20 seconds.
3
Release the button and check that the flame stays lit.
If it does not, check the thermo element (above).
If you already have checked the thermo-element (above),
replace the thermo-element.
If it is still not working, also replace the flame failure device.
clEaNiNg thE buRNER aND buRNER jEt
The main steps when cleaning the burner
and the burner jet are:
1
Shut the gas valve.
2
Remove possible cover plates for access
to burner and burner jet.
3
Unscrew the burner jet which is located on
the gas inlet side of the burner.
4
Clean the burner jet carefully with alcohol
or petrol and blow it dry.
5
Clean the burner with a brush and blow it
free from dust.
6
Assemble the parts again.
www.sibir.com
1
!
!
If the flame is blown out, the flame
failure device must shut off the gas
supply within minutes. Test as follows:
1 Blow out the flame, wait 1–2 minutes.
2 Try to light the burner without pres-
sing the flame failure device button.
If functioning correctly, it will be impos-
sible to light the flame without pressing
the button.
Burner jet
· Do not use any tools for cleaning burner jets.
· Do not use other burner jet sizes than the one
recommended for the refrigerator model.