ElEctRical opERatioN: REFRigERatoR Not cooliNg at all [a]
1
Cooling unit at the cabinet rear warm?
2
Ventilation provided around the cooling unit?
3
Is the refrigerator levelled?
4
Is the room temperature lower than 43°C?
5
Run the refrigerator for two hours. Tilt the unit
slightly forwards (towards the front) until it reach-
es an angle of 15-25°.Maintain this position for
60 seconds then return the refrigerator to a level
position again. Open the freezer door. Put your
hand against the rear wall of the freezer compart-
ment. Is it getting colder?
6
The refrigerator should now be operating normally.
ElEctRical opERatioN: REFRigERatoR Not cooliNg at all [b]
1
Is the supply cable plugged in?
2
Is the energy selector set to position I?
3
Does other equipment function in the
refrigerators wall socket?
4
Control knob in high figure position?
5
Check the thermostat and heater.
www.sibir.com
YES
YES
YES
YES
YES
YES
YES
YES
YES
See chart [B] below.
NO
Arrange for ventilation.
NO
Level the refrigerator.
NO
Place the refrigerator in a colder place.
NO
NO
Replace the cooling unit.
Plug into the wall socket.
NO
Set it to position I.
NO
Check and if necessary replace the buildings
NO
electrical fuse. If neccessary call an electrician.
Turn the knob to highest figure position.
NO
18