chEcKiNg thE gaS EquipmENt FoR lEaKS
1
Dissolve some soap in a small quantity of water.
Brush all equipment joints with soapy water.
2
3
Watch the joints for bubbles.
4
Bubbles indicate a leak. A leaking joint must be attended to
either by tightening or replacing the leaking part.
DEFRoStiNg
It is normal that frost forms on the cooling element. A thin layer of frost does not affect the cooling
performance. A thick layer of frost (6–10 mm or 1/4–3/8 inch or more) must be removed by defrosting.
1
Move the vaccine to another refrigerator if available or store it in a
coolbox with ice packs.
2
Turn off the refrigerator and leave the door and the freezer
compartment shutter open.
3
Remove ice with your fingers, as soon as it is possible to do so.
Do not use knives or sharp instruments!
4
Empty the drip tray.
5
Wipe the freezer compartment and cooling element dry.
6
Clean the refrigerator inside. Use mild detergent only.
7
Start the refrigerator on gas or electricity.
!
· Defrosting is to be carried out as quickly as possible in order not to damage the vaccine.
· Use the time it will take to defrost to clean the refrigerator etc.
· Wait until the vaccine compartment is cold before replacing the vaccine.
www.sibir.com
2
8
copyright © sibir international