REplaciNg thERmoStat
The main replacement procedure is the following:
1
Shut the gas valve at the gas bottle and/or pull out the plug
from the wall socket.
2
Remove the capillary tube end from the cooling element
and pull it gently out of the cabinet.
3
Remove the cover from the gas assembly.
4
Detach the turner from the gas valve.
5
Use a flat screwdriver to separate the gas valve from the
thermostat, see illustration below.
6
Disconnect the thermostat from the flame safety device.
7
Remove all electrical cables from the thermostat. Attach
the cables to the new thermostat.
8
Change to new O-rings and push together the different
parts.
9
Replace the cover.
10
Reattach the capillary tube end to the cooling element.
REplaciNg thE hEatER
1
Remove the plug from the wall socket.
2
Remove the cover from the gas assembly and loosen
the heater cables.
Look for a small cover on the boiler case and remove it.
3
4
Lift the heater and take it out.
5
Insert the new heater into the heater tube.
6
Make sure that the glass wool is put back around the
heater and fit the cover again.
7
Connect the cables and fit the cover in reverse order.
8
Put the refrigerator to test.
www.sibir.com
!
BE CAREFUl noT To BREAk THE
CAPIllARy TUBE!
Cover
Heater
12
copyright © sibir international