Remark:
The pump is delivered with self-priming enabled. Each time the pump restarts, it will perform
self-priming automatically. The user can enter the parameter setting to disable the default
self-priming function (see 5.7)
If the default self-priming function is disabled, and the pump has not been used for a long
time, the water level in basket may drop. The user can manually activate the self-priming
function by pressing both
(default value is 600s). After manual self-priming has been completed, the pump will return
to its previous status before activating the manual self-priming mode.
The user should press
5.4 Backwash
User can start the backwash or fast re-circulation in any running state by pressing
Default
Time
180s
Running capacity
100%
Exit backwash
When the backwash mode is on, users should press
return to the normal operating status before backwash.
5.5 Setting the running capacity
1
Press
for more than 3 seconds to unlock the screen.
2
Press
priming.
3
Press
capacity by 5%
4
Press
It will return to the running capacity displayed after 10s without operating.
Note:
a. When
the running capacity is adjusted, the system will automatically save the latest setting.
b.
When setting full speed, the pump will automatically increase the speed if the pipeline's resistance is high, but will
not exceed the power rating of each model.
and
for 3 seconds. The adjustable time is from 600s to 1500s
for more than 3 seconds to exit the manual self-priming mode.
Setting range
Press
or
to adjust from 0 to 1500s with 30 seconds for each
step
80~100%, enter the parameter setting (see 5.7)
to start. The pump will run at 80% of its running capacity on initial startup after self-
or
to set the running capacity between 30% and 100%; each step increases the
for more than 3 seconds to read the real-time power capacity.
11
for 3 seconds to exit it. The pump will
.