1) DESTINATION OF USE
This product is destined exclusively for the opening and closure of swing doors for the passage of vehicles, characterised by dimensional
limits and weight as indicated in this manual in the "Limits of use" paragraph.
No other use is allowed.
Automatismi Benincà is not liable for uses that are not in compliance with those indicated in these instructions.
2) LIMITS OF USE
Table indicates the maximum values (weight by leaf length) acceptable for the TOM automation
Door leaf width
TOM.30M / TOM.30ME / TOM.3024E
2.0 m
2.5 m
3.0 m
3.5 m
4.0 m
4.5 m
5.0 m
3) INTRODUCTION
•
Before installing the system, read the instruction herein.
•
It is mandatory not to use the TOM item for applications different from those indicated in the instructions herein.
•
Supply the end user with instructions for using this system.
•
The end user should receive special instruction manual.
4) PRELIMINARY CHECKS
It is indispensable to carry out several checks before starting installation:
• Try and open the gate manually, the leaves must move without effort and without points of resistance for the entire run.
• When left in any intermediate position the leaf must not move.
• The hinges and components subject to wear must be in perfect working condition. If this is not the case, replace the faulty parts.
• The door structure must be strong and the leaves rigid.
• With the gate completely closed, check that the leaves are aligned perfectly along their entire length.
• The pillars supporting the leaves must be suitable for fixing the gear motors.
Figure 1 shows the main overall dimensions.
Different versions are available with 300/400/500mm stroke (Fig.1 ref. A).
230 and 24 V versions with encoder or electromechanical limit switches are also available (see Technical Data table).
TOM has adjustable mechanical stops both in opening and closing. However, a stop for closure on the ground is recommended (fig.3).
The reliability and safety of the automation depend on the state of the gate structure.
Check that there is enough space for installation of the operator in safe and comfortable conditions.
5) FITTING THE AUTOMATIC SYSTEM
Stabilise the height of the automatic system above ground level (it should be as central as possible with respect to the gate and cor-
responding to a sturdy cross piece).
Then weld the plate P (fig. 5) respecting the distances in fig. 2 and 4.
When the gate is closing, weld the bracket S(Fig.5) respecting the distance in fig. 2/4, onto a cross piece of the gate or another suitably
robust element; bear in mind that in this condition the actuator must not be completely at the end of travel.
After fixing plate P and bracket S, proceed with fixing the actuator using screw V and nut D (fig.5) for fixing to the pillar.
IMPORTANT: Insert washers R (9x17 and 10x30) as shown in Figure 5.
For fixing to bracket S use screw V2 and nut D.
Note:
Bracket P and its bracket on the actuator have different bore holes to allow for different fixing dimensions.
Most of the installation dimensions in Fig. 2 require the bracket P to be cut, some dimensions that do not require cutting are highlighted
6) HOW TO ADJUST THE MECHANICAL STOPPERS
The actuator is provided with adjustable mechanical stoppers in the opening and closing phases.
The system is adjusted by suitably positioning the "Open" and "Close" mechanical locks, as shown hereunder (Fig.8/9):
1) Remove the two screws V (Fig.7) and remove the cover and rotate it 180, so that the cover T can be removed.
2) Unlock the automation, using the special release lever, as indicated in the "EMERGENCY MANOEUVRE" paragraph.
3) Move the leaf to the OPEN position.
4) Loosen the Vo screws (hexagonal spanner size 5) and move the "OPEN" block until it comes to a stop, fasten the Vo screws.
5) Move the sash to the CLOSED position.
6) Loosen screws Vc and move the "CLOSE" block until it stops, fasten screws Vc.
7) Resume automatic operation.
ATTENTION: In the TOM 30M/40M/50M models, the electromechanical limit switches are integral with the mechanical block
7) ELECTRICAL CONNECTIONS
1) The special plate P (Fig. 6) allows for using a link for sheath or cable gland r PG13,5.
Once the type of cable gland is applied to the plate, fix the latter to the adaptor cover by means of screws V.
n the 230V versions, after carrying out the wiring, fasten the capacitor using the appropriate support shown in Fig.7.
Figure 10 shows the connections for the various TOM models.
2) It is mandatory to provide for ground by using the special GND terminal.
500 kg
400 kg
300 kg
TOM.40M / TOM.4024E
600 kg
500 kg
400 kg
350 kg
300 kg
TOM.50M / TOM.50ME / TOM.5024E
700 kg
600 kg
500 kg
400 kg
350 kg
300 kg
250 kg