4. Operation
4.1 Power ON/OFF
Once the unit has been properly installed and the batteries are connected well, simply
press ON/OFF switch to turn on the unit (button located on the bottom of the inverter).
4.2 Operation panel
The operation and display panel, shown in below image, is on the front panel of the
inverter. It includes three LED indicators, four function keys and a LCD display , indicating
the operating status and input/output power information.
LED Indicator
Solid on
AC/INV
Green
Flashing
CHG
Yellow
Flashing
Solid on
Fault
Red
Flashing
Function
keys
MENU
Press to restart or choose previous selection.
UP
Increase the setting data.
DOWN
Decrease the setting data.
Enter setting mode and confirm the selection in setting mode go to next selection or
ENTER
exit the reset mode.
Messages
Output is powered by mains in serial mode
Output is powered by battery or PV in battery mode
Battery is charging or discharging
Fault occurs in the inverter/charger
Warning condition occurs in the inverter/charger
Description
53