33
Battery
equalization time
34
Battery
equalization
timeout
35
Equalization
interval
36
Equalization
activated
immediately
37
BMS control
method
38
Battery stop
discharging
percent when
SOC is available
39
Battery stop
charging percent
when SOC is
available
40
BMS
communication
41
Lithium battery
protocol
After pressing and holding "MENU" button for 6 seconds, the unit will enter reset model.
Press "UP" and "DOWN" button to select programs. And then, press "ENTER" button to
exit.
Setting range is from 5 min to 900min.
Increment of each click is 5 min.
Setting range is from 5 min to 900min.
Increment of each click is 5 min.
Setting range is from 0 to 90 days. Increment
of each clink is 1 day.
If equalization function is enable in program 30, this program can
be set up. If "enable" is selected in this program, it is to activate
battery equalization immediately and LCD main page will shows
"
". If "disable" is selected, it will cancel equalization function
until next activated equalization time arrives based on program
35 setting. At this time, "
too.
Setting range is from 20% to 100%. Increment
of each click is 1%.
Setting range is from 20% to 100%. Increment
of each click is 1%.
When the communication between BMS and
inverter is faulted, the inverter still charge or
discharge from the battery.
When the communication between BMS and
inverter is faulted, the inverter stop charging or
discharging from the battery.
Setting range is from 0 to 31. Increment of
each click is 1.
If LI is selected in program 14, program 41 can be set. After the
program 41 is set, please restart the inverter to take effect. For
example, if you set the program 41 to 0, the inverter can
communicate with the must lithium battery.
Reset setting disable
Reset setting enable
60
" will be shown in LCD main page