1. Operating instruction
1.1 Switching on the Unit
The unit may be switched on (setting I) or off
(setting O) by using the switch (1) on the right
hand side panel.
1.2 Heater
Turning the temperature selector (2) to the left
will turn on the heater and select the required
temperature. Once turned on, the heater will
warm the room uniformly and quickly. Air enters
the heater from below where it is heated and
then exits through the grid at the top of the
heater. The room temperature can be infinitely set
bet ween approx. 6 °C and 30 °C. The thermostat
switches the heater off once the set temperature
has been reached and switches on and off inter-
mittently to maintain the required temperature.
3
4
T ABDECKEN -
HE HAKPÛBATb -
NE PAS COUVRIR - DO NOT COVER
RZYKRYWAC - NIET AFDEKKEN - NEZAKRYVAT - NO CUBRIR
If uniform temperature is required in two rooms,
do not set both heaters to the same setting. The
same applies to two heaters installed in the same
room.
In order to minimize energy usage when airing
the room by opening the windows, it is advisable
to switch off the unit.
1.2.1 Anti-frost setting
Set the temperature selector (2) to
The thermostat will switch the heater on auto-
matically if the room temperature drops below
approx. +6 °C. Ensure the correct heater is fitted
to cope with the demands to be made upon it.
1.2.2 Limiting the temperature range
In order to lock the selector at a specific tempe-
rature, remove the two pins (3) from the rear of
8
2
5
.
for the user and the professional
the housing and insert either side of the desired
setting. The two pins may also be used to limit a
temperature range.
2
1
1.3 Safety notes
The appliance must not be operated:
– In areas which are subject to the risk of fi re
or explosion due to chemicals, dust, gases or
vapours;
1
– In the immediate vicinity of pipes or contain-
ers which carry or contain combus tible or
potentially explosive substances.
For this reason, the minimum clearance inter-
vals must not be undercut.
In workshops or other areas in which the
odour of waste gases, oil, petrol, etc. might oc-
cur, or in which work is carried out involving
solvents and chemicals, there is a risk of sus-
tained odour burdens being engendered, and
possibly of dirt contamination occurring.
The air outlet must not be obstructed. For safe-
ty reasons the upper and lower air grilles must
never be covered with items such as washing
nor obstructed by items in too close proxim-
ity (see fi gure 3). Objects should not be leant
against the unit nor placed between the unit
and the wall. Never leave combustible materials,
such as wood, paper, textiles or fl ammable items
such as wax, petrol, aerosol cans etc. in the
vicinty of the warm air outlet.