Descargar Imprimir esta página

Balluff BTL AK5A00-0930-C11WH120-000C51-001 Manual De Instrucciones página 43

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 93
BTL AK _ A00- _ _ _ _ -C11WH120-000C51-001
Magnetostrictive Linear Position Sensor – Rod Style
8
Technical data
The specifications are typical values at 24 V DC, room
temperature and a measuring length of 500 mm in
conjunction with the magnet BAM TG-TL-044 or another
compatible magnet (see Accessories on page 21).
The product is immediately ready for operation, full
accuracy is achieved after the warm-up phase.
Further data can be found at www.balluff.com
on the product page.
8.1
Ambient conditions
Ambient temperature
Storage temperature
Relative humidity
Operating pressure
Short-term pressure load
Typ. temperature coefficient
2)
Shock rating as per
EN 60068-2-27
3), 4)
Continuous shock per
EN 60068-2-27
3), 4)
Vibration as per
EN 60068-2-6
3), 4)
Protection class according to
IEC 60529 (in screwed
condition)
5), 6)
8.2
Detection range/measuring range
Measuring length
Resolution
Position
Velocity
Repeat accuracy
Measuring interval (internal)
Linearity deviation
7)
Detectable velocity
www.balluff.com
1)
−40...+75 °C
−40...+100 °C
≤ 100%
≤ 230 bar
450 bar (10 × 1 min)
≤ 5 µm + 10 ppm/K
100 g/6 ms
50 g/2 ms
12 g, 10 ...2000 Hz
IP65
25...1830 mm
≥ 5 µm (adjustable via
SDO in increments of
5 µm)
≥ 0.1 mm/s (adjustable
via SDO in increments
of 0.1 mm/s)
≤ ±5 µm
3.5 ms
≤ ±100 μm
≤ 10 m/s
8.3
Electrical data
Operating voltage U
8)
B
Current draw
Power consumption
Overvoltage protection
Voltage-proof up to (GND – Housing) 500 V DC
CANopen terminating resistor
8.4
Electrical Connection
Short-circuit protection
Protected against polarity reversal
For UL: Only use in enclosed spaces.
1)
Measuring length 500 mm, magnet in the middle of the measuring range
2)
Individual specifications as per Balluff standard
3)
4)
Resonant frequencies excluded
IP rating was not evaluated by UL
5)
For UL: Type 1
6)
Configuration for one magnet
7)
For UL: The BTL must be externally connected via a limited-energy circuit
8)
as defined in UL 61010-1, a lo-power source as defined in UL 60950-1 or
a class 2 power supply as defined in UL 1310 or UL 1585.
20.4...28.8 V DC
≤ 75mA
≤ 1.8 W
U
to 36 V DC
B
120 Ohm
Signal output to
GND and to
30 V DC
U
to 30 V DC
B
english
19

Publicidad

loading