2. Intended use
The MENZER industrial vacuum cleaner VCM
330 is intended for use as a wet & dry vacuum
cleaner for the cleaning of floor and wall areas in
outdoor and indoor spaces and for the vacuum-
ing and separation of dry, non-flammable and
non-explosive dusts, of non-flammable and
non-explosive liquids and of water/air mixtures
in non-hazardous areas. The vacuum cleaner
is not intended for the vacuuming of foams. The
vacuum cleaner is suitable for private and profes-
sional use, e.g. in workshops, hotels, schools,
hospitals, factories, shops, offices and rented
premises. This machine must be used with filter
elements and fleece filter bags recommended by
MENZER only.
3. Technical specifications and emissions
Dimensions/Vacuum cleaner parameters
Length x Width x Height [mm]
(Intrinsic) weight (incl. cable 5 m) [kg]
Weight (incl. standard accessories) [kg]
Container volume [l]
Liquid fill level [l]
Mains voltage / Supply frequency
Rated output
Max. power consumption
Connected power socket load (min./max.)
Max. overall power consumption
Max. air volume flow at motor
Max. negative pressure at motor
Protection class
Protection type
Dust class
Filter area
Power cable / length
4 GB
The vacuum cleaner VCM 330 is suitable for dust
class M and bears the relevant certification mark.
Vacuum cleaners for dust class M in compliance
with EN 60335-2-69 are intended for the removal
and separation of dusts posing a moderately
health hazard and an exposition limit value of
> 0,1mg/m³.
The vacuuming of carcinogenic substances (except
wood chips) or substances carrying pathogens is
prohibited.
Caution! The owner/operator is liable for
any improper use!
VCM 330
400 x 350 x 700
7
7.5
30
18
220–240 V ~ 50 Hz
1190 W
1400 W
30 W / 2000 W
3400 W
2,800 l/min
21,5 kPa / 215 mbar
/ I
IPX4
M
> 0.230 m²
3 x 1.0² – H07RN-F / 5 m
Sound pressure level LpA
Sound power level LwA
Prediction sound emission KpA
Vibration emission value
Determined in accordance with testing conditions set out in EN 60335-1 and EN 60335-2-69 with new power tool without wear.
Values will change with regular use, wear, environmental conditions and insufficient maintenance. The stated values were
determined under laboratory conditions and are insufficient for a risk assessment. The actual values applicable at the relevant
workplace and under actual work conditions depend on environmental conditions, work practices, duration of operation and
the substances being removed. MENZER GmbH cannot be held responsible where these stated values are used instead of actual
emission values in any individually required risk assessment.
4. Safety information
4.1 General information
Caution! Please read all safety information and
instructions! Please also note all warning and
notification signs attached to the machine.
• Store the operating manual in a safe place for
future use.
The regional general health and safety regulations
must be complied with in addition to the instruc-
tions contained in this manual.
• WARNING – The device must only be operated
in accordance with its intended use. Any work
performed with the device, for which it was not
designed, may result in damage to assets and
injury to personnel.
• WARNING – Non-compliance with the manual
and other information or compliance errors may
result in electrocution, fire and/or severe injuries.
• This device must not be operated by persons
with physical/mental disabilities or physical per-
ception impairments or which are not familiar with
the use and handling of this device type. Children
are not permitted to operate this device!
• The use of this device by adolescents within the
scope of professional technical training is permit-
ted. The stipulations set out in the Youth Work
Protection Act (JArbSchG) apply.
81 dB(A)
92 dB(A)
3 dB(A)
<2.5 m/s²
• Children must be kept at a safe distance to the
vacuum cleaner during operation, and the device
and its packaging must also be stored out of the
reach of children.
• Do not allow any person to operate the device,
who has not read the operating manual.
• You and all other persons in the work area, who
must remain at a safe distance to the device, must
wear hearing protection.
• Do not leave the device unattended while in
operation.
• Never give in to overconfidence when working
with the device and do not ignore any of the safety
rules for vacuum cleaners, even if you are very
familiar with its operation.
• Be attentive, concentrate on your work and use
common sense in all tasks involving a vacuum
cleaner. Do not operate a vacuum cleaner while
you are fatigued or under the influence of drugs,
alcohol or prescription medication.
• Safety features must never be bypassed or modi-
fied in any way as they are put in place for your
protection.
• Defective devices must only be repaired by
MENZER Service.