Following the weight measurement, impedance will be measured for the analysis: the upper body using the 4
electrodes on the control unit, and the lower body using the 4 electrodes on the scale. This is indicated by the
symbol showing current passing through the body.
The overview is displayed.
The measured value is automatically saved when switching off.
Note: The measurement will not be saved if the following applies:
The user is not automatically detected. This happens if your measured weight differs from the previous
measurement by +/3 kg or if another user has similar values (+/3 kg) to yours. In this case, press the [
button to select the user manually.
The user is standing on the scale with shoes on and is not holding the handheld unit.
Analysis of measured values
The results will be analysed automatically after taking the measurement or after selecting the user manually on
the control unit.
Graphic representation
a) Weight
– Press the menu button [
menus or the memory.
The trend for your body weight is shown from measurement to measurement.
Later measurements are added on the right. The reference line shows your tar-
get weight.
You can change your target weight in the user data at any time.
b) Body fat
– Use the [
,
] buttons to switch to showing body fat values.
The trend for your body fat is shown from measurement to measurement. The
reference line represents the average value for all body fat measurements; the
bars show whether the values have gone up or down.
Upper body, lower body
a) Body fat
– Press the [
] button on the control unit to switch to the detailed view for the
upper/lower body.
The current body fat measurement is displayed for the whole body and is subdi-
vided into upper body/lower body.
b) Muscle
– Use the [
,
] buttons to show the detailed muscle mass view.
Only the current measurements can be shown, not the old stored meas-
ured values.
] on the control unit to switch to the individual sub-
24
26-07-2017
]
26-07-2017
26-07-2017
26-07-2017
26-07-2017