Display
Cause
ERROR:_DATA
The BIA was successful, but the fat per-
centage is outside the measurable range
(less than 5% or greater than 50%).
Empty display
The batteries in the control unit are com-
pletely flat.
The batteries have not been inserted in
the control unit correctly.
Only weight is dis-
Unknown measurement as it is outside the
played, no diag-
user assignment limit or a unique assign-
nosis
ment is not possible.
No measurement possible
Possible faults
The control unit was not activated before
stepping onto the scale.
Radio connection between scale and con-
trol unit interrupted.
The control unit is too far from the scale.
The batteries in the scale are flat or have
been inserted incorrectly.
Incorrect weight measurement
Possible faults
Incorrect zero point of scale.
Scale is on a carpet.
Incorrect weight is displayed.
Incorrect weight is displayed.
Solution
Please repeat the measurement barefoot, or
with the soles of the feet lightly dampened
if necessary. If necessary, change your set
activity level.
Replace the batteries (see section 12).
Check the polarity is correct, (see page 20).
Select user on the scale using the "
or repeat user assignment in the app.
See section 9.
Solution
Switch the control unit on before taking the measurement. If nec-
essary, wait 30 seconds and then repeat the measurement.
Re-insert the batteries in the scale and control unit.
Ensure a sufficient distance from strong electromagnetic fields.
Reduce the distance between the scale and the control unit to a
maximum of 2 metres.
Change the batteries and check the polarity is correct.
Solution
Just before taking the measurement, activate the scale with the
foot until the operating status
Wait approx. 5 seconds and repeat the measurement. For your
information: because you step on the scale straight away in nor-
mal use, the scale saves the zero point when the scale is switched
off (when the operating status indicator
Place the scale on a flat, solid surface.
Stand on the outside of the scale as far as possible without it tip-
ping.
Stand as still as possible.
Wait until the scale switches itself off. Then repeat the measure-
ment.
29
appears in the display.
goes out).
" button