Descargar Imprimir esta página

Beurer BM 64 Manual De Instrucciones página 34

Ocultar thumbs Ver también para BM 64:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Error
Possible cause
message
There are
problems with
the connection
between the
smartphone/tab-
let and the app.
The batteries are
nearly flat.
10. DISPOSAL
Repairing and disposing of the device
• Do not repair or modify the device yourself. Proper operation
can no longer be guaranteed in this case.
• Do not open the device except for the battery compartment.
Failure to comply will invalidate the warranty.
• Repairs must only be carried out by Customer Services or au-
thorised retailers. Before making a complaint, first check the
batteries and replace them if necessary.
• The device must not be disposed of with household waste.
Dispose of the device at a suitable local collection or
recycling point in your country. Dispose of the device in
accordance with EC Directive – WEEE (Waste Electrical
and Electronic Equipment). Please contact the local authori-
ties responsible for waste disposal if you have any questions
regarding disposal.
Disposal of the batteries
• Used, completely discharged batteries must not be disposed
of with household waste. Dispose of the batteries in specially
Solution
Switch off the main unit,
close the app and first
deactivate Bluetooth
®
on your
smartphone/tablet before
reactivating the function. Try to
establish the connection again.
Insert new batteries into the
device.
designated collection boxes, at recycling points or at electron-
ics retailers. You are legally required to dispose of the batteries
correctly.
• The codes below are printed on batteries containing harmful
substances:
- Pb = battery contains lead
- Cd = battery contains cadmium
- Hg = battery contains mercury
11. TECHNICAL SPECIFICATIONS
Type
BM 64
Measurement
Oscillometric, non-invasive blood pressure
method
measurement on the upper arm
Measurement
Cuff pressure 300 mmHg,
range
systolic pressure 50 – 280 mmHg,
diastolic pressure 30 – 200 mmHg,
pulse 40 – 199 beats/minute
Display
Systolic pressure ± 3 mmHg,
accuracy
diastolic pressure ± 3 mmHg,
pulse ± 5% of the displayed value
Measurement
Max. permissible standard deviation according
uncertainty
to clinical testing: systolic pressure 8 mmHg,
diastolic pressure 8 mmHg
Memory
2 x 120 memory spaces
Dimensions
L 143 mm x W 105 mm x H 60 mm
Weight
Approx. 450 g (without batteries, with cuff)
Cuff size
22 to 42 cm upper arm circumference
Operating
+ 10 °C to + 40 °C, < 90 % relative humidity,
conditions
800 – 1050 hPa ambient pressure
34

Publicidad

loading