Descargar Imprimir esta página

Simer VT14 Manual Del Usuario página 5

Tanques de presion precargada
Ocultar thumbs Ver también para VT14:

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
TESTING FOR BLADDER LEAKAGE
Step 1. Disconnect power to pump.
Step 2. Drain water from tank bladder by opening
faucet closest to tank.
Step 3. Remove valve cap and release all pressure by
depressing valve core. When air stops coming
from valve, remove valve core to release
remaining pressure.
Step 4. Disconnect piping from elbow on tank cover
flange.
Step 5. Carefully turn tank upside down or lay on its side.
Retained water in tank may cause sudden
weight shift when lowering. Support tank so it cannot
fall when being lowered or inverted.
Step 6. If bladder leaks, water will run out of valve. If
so, replace bladder.
Step 7. If replacing bladder, be sure air and water
pressures are relieved before removing cover
flange. When reassembling cover flange, do
not tighten nuts or mounting studs more than
85 in-lbs. (9.6 Nm).
NOTICE: When using metal pipe with plastic fittings use
only Teflon tape or Plasto-Joint Stik
Maximum
to Standard
Catalog
Capacity
Number US Gals (L)
HT7-01
6 (23)
VT14
14 (53)
VT20
19 (72)
VT36
35 (132)
VT52
50 (189)
VT96
85 (322)
* Length overall; this model is a horizontal tank.
For parts or assistance, call Simer Customer Service at
1
on male threads.
Product Information – Pre-Charged Tanks
Equivalent
Tank
Tank US
Diameter
Gals (L)
(mm)
15 (57)
12" (305) *16-1/2" (419)
30 (114)
16" (406)
42 (159)
16" (406) 30-1/8" (765)
82 (310)
20" (508) 36-1/4" (921)
120 (454)
24" (610) 34-3/4" (883)
220 (833)
24" (610)
Pressure
Pressure
Gauge
Switch
From Well
Figure 5: Typical installation with vertical pre-charge tank and
submersible well pumps
NOTICE: Most standard tanks have separate inlet and
outlet ports. Pre-charge tanks have one port serving both
functions. When replacing standard tank with a pre-
charge tank, run pipe from pump into a tee as shown.
2nd leg of tee goes to tank elbow; 3rd leg goes to exist-
ing service.
Tank
Tank
Height
Discharge
(mm)
Tapping (138-276kPa) (207-345kPa) (276-414kPa)
3/4"
23" (584)
1"
1"
1"
1-1/4"
54" (1372)
1-1/4"
30.0 (113.6)
1-800-468-7867 / 1-800-546-7867
To service
Pressure
Relief Valve
Drawdown - Gals (L)
20-40 PSI
30-50 PSI
2.2 (8.3)
1.8 (6.8)
4.8 (18.2)
4.1 (15.5)
6.9 (26.1)
5.8 (22.0)
12.7 (48.1)
10.7 (40.5)
18.3 (69.3)
15.5 (58.7)
26.0 (98.4)
5
40-60 PSI
1.6 (6.1)
3.6 (13.6)
5.0 (18.9)
9.3 (35.2)
13.4 (50.7)
22.0 (83.3)

Publicidad

loading

Este manual también es adecuado para:

Ht7-01Vt20Vt36Vt52Vt96