Descargar Imprimir esta página

Unipro UNI POOLS 14 Manual De Instrucciones página 12

Jacuzzi hinchable

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 48
22
7.
Repair Kit
8.
Tarpaulin
CONTROL PANEL DESCRIPTION
A
B
G
F
C
FILTER
TEMPERATURE
BUBBLE
D
E
HEATER
A.
Temperature increase button
B.
Filtering system On/Off button
C.
Air bubbles On/Off button
D.
Heating water On/Off button
E.
Temperature decrease button
F.
Entry button in temperature settings
G.
Display
For informational purposes only:
Ambient temperature and initial water temperature
are the factors for heating duration. Current water
temperature will be displayed after filter system has been
running for at least one minute.
Ambient
Water
Set
Heating
Temperature
Temperature
Temperature
Duration
50°F (10°C)
50°F (10°C)
104°F (40°C)
23h
59°F (15°C)
59°F (15°C)
104°F (40°C)
18h
68°F (20°C)
68°F (20°C)
104°F (40°C)
14h
77°F (25°C)
77°F (25°C)
104°F (40°C)
11h
86°F (30°C)
86°F (30°C)
104°F (40°C)
8h
3.2. PREPARING FOR USE
APPLIANCE LOCATION
The temperature of environment must not be higher
than 40°C and the relative humidity should be less than
85%. Keep the device away from hot surfaces. Operate
the device on flat, stable, clean, refractory and dry
surfaces out of the reach of children and people with
mental disabilities. The surface should be free of dirt
and sharp edges, and able to resist the weight of the
mass of the device filled with water and users. The area
around the device should have drainage in order to
easily drain the spilled water. The surface around the
device should be slip-resistant.
Always place the device on properly unfolded tarpaulin.
When installing the device inside a building, additional
requirements should be met, i.e.:
no hazards due to increased humidity in the
room,
ensure adequate ventilation,
the floor must withstand the weight of the device
with water and users,
it is not recommended to install the device on
upper floors because of the risk of flooding the
rooms below with water,
the drainage of water to the sewage system
should be ensured,
it is forbidden to place the device on rugs or other
materials susceptible to moisture.
The power cord connected to the appliance must be
properly grounded and correspond to the technical
details!
INSTALLING THE APPLIANCE
Take the product out of the packaging. Spread it
out and make sure that the pool and cover are
right-side up.
Open the air outlet from the pool and screw on
one of the hose ends.
Open the air valve and attach the other end of the
hose to the valve.
Connect the device to the power supply.
Press the On/Off bubble button on the control
panel. Wait for the pool to inflate, taking care not
to exceed the maximum air filling.
Press the On/Off bubble button to stop the filling
process.
Unscrew the hose from the outlet and air valve,
close the inlet and close the valve.
Screw the filter to the pool wall by turning it
clockwise.
Fill the pool with water to a point between the
maximum and the minimum level.
Cover the jacuzzi pool with a cover.
PLEASE NOTE: If you want to pump up the water-filled
pool, turn the nozzles on for 2-3 minutes by pressing the
On/Off button for the bubbles and remove the air filter,
and then follow the steps described above.
CAUTION: After the first pumping, it is natural
that the material may stretch. Reinflation is
needed to get the correct pressure.
3.3. DEVICE USE
Powering the device
The device is equipped with a power cord with
a residual-current device (circuit breaker). The circuit
breaker should be tested regularly. For this purpose,
reset the switch by pressing the Reset button. Start any
of the jacuzzi functions, e.g. air bubbles, and then press
the TEST button. The switch should cut off the power
supply from the device. Press the RESET button again to
return to the normal operating mode.
PLEASE NOTE: If, after pressing the TEST button, the
switch does not cut off the power supply from the
device, immediately stop using the jacuzzi and contact
the manufacturer's service department.
Water filtration function
Press the filtration On/Off button. The device will
begin to filter, the diode will light on the button.
Pressing the filtration On/Off button again will
turn off the filtering process, the LED on the
button will go off.
When the filter pump runtime exceeds 168 hours,
„FC" will appear on the display and a signal will
be displayed. This will be information about the
need to replace or clean the filter. The LED on the
filter button will be lit, but the filtering itself will
be turned off. Other device systems will also not
work. To turn off the message, press the filtration
On/Off button, the current water temperature
will appear on the display. To restore the filtration
system activity, replace or clean the filter.
Massage function with air bubbles
Press the On/Off button for the air bubbles. The
device will start to spray air into the water in front
of the nozzles, the diode will light on the button.
Do not activate the function if a cover is placed
on the pool.
Pressing the bubbles On/Off button again will
turn off the bubble release process, the LED on
the button will go off.
The nozzle system automatically stops working
after 20 minutes. To restart the function, wait 10
minutes.
For the first 15 minutes of the function it can be
turned off and turned on without interruption.
After the time of 15 minutes has elapsed after
switching off the air bubble function, wait 10
minutes before turning it on again.
Water heating function
Press the On/Off button to heat the water. The
device will start to heat up the water, the diode
will light on the button. It will also light up the
diode on the filtering On/Off button. The device
will also start filtering the water.
After reaching the set water temperature
(temperature setting is described in the following
point) + 1°C, the heating will be automatically
switched off, but the filtering will continue to
function. The control diodes for heating and
filtering will light up constantly, even after the set
water temperature has been reached.
If the water temperature drops 2°C below the set
value, the heating system switches on again (the
filter will continue to run).
23
During the warming process, pressing the
warming button again will switch off the warming
function and its control diode, but filtering will
continue to work for 2 minutes and during this
time the control diode for filtering will light up in
pulses.
Setting the water temperature
Press the entry button to set the temperature, the
display will flash.
Use the buttons to increase or decrease the
temperature value to set the preferred value.
Press the input button again to set the
temperature to confirm the entered value.
1.
The water heating process depends on
the initial water temperature and external
conditions and it takes around 12-24h.
For a water with temperature of 15°C (tap
water), in ideal conditions, heating time will
take 15h to increase the water temperature
up to 30°C.
2.
The heater is mainly used to maintain the
water temperature, we recommend filling
the jacuzzi with warm water.
3.
The product with clear signs of use, water or
dirt residues is not subject to return.
Keeping water clean
In order to keep the device in good condition and
not to expose yourself and other users to health
problems, you should regularly clean the water in
the pool.
Water should be periodically cleaned with
chemicals or replaced with fresh water. It is
forbidden to use chemicals with calcium ions.
When
using
chemicals,
follow
manufacturer's
recommendations
and
instructions for use, and consult with local
authorities regarding the permissible use of these
products
Replace and clean the filter regularly. It is
recommended to clean the filter after every 72-
120 h of use. The filter should be replaced once
a month depending on the intensity of use.
The pH of the water should be maintained at 7.2-
7.8, total alkalinity between 80 and 120 ppm, free
chlorine between 3 and 5 ppm. It is recommended
to use special tests to check the water status.
Tests should be used in accordance with the
recommendations and instructions of their
manufacturer.
Cleaning the filter
Disconnect the device from the power supply
Unscrew the filter from the pool wall.
the

Publicidad

loading

Productos relacionados para Unipro UNI POOLS 14

Este manual también es adecuado para:

Uni pools 15Uni pools 16Uni pools 17Uni pools 18Uni pools 19