READING THESE INSTRUCTIONS IS IMPORTANT FOR PERSONAL SAFETY. READ THE FOLLOWING REMARKS CAREFULLY BEFORE
PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
ORIGINAL INSTRUCTION MANUAL. NOT READING THESE IMPORTANT INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING ORDER
OF THE SYSTEM AND CREATE DANGER SITUATIONS FOR THE USERS OF THE SYSTEM. SAVE THESE INSTRUCTIONS FOR FUTURE USE.
THE INTEGRATED CARDIN SYSTEMS ARE DESIGNED
AND BUILT ONLY TO BE USED IN MADE TO MEASURE
METALLIC STRUCTURES. CARDIN ELETTRONICA DO NOT
GUARANTEE PRODUCTS THAT HAVE BEEN INSTALLED
IN A WAY THAT DOES NOT CONFORM TO THE SUPPLIED
INDICATIONS.
It therefore follows that the structure should be constructed in
such a way as to guarantee the following characteristics:
• Suitable for housing electronic appliances:
- the upper part must be completely sealed, so as not to allow
water infiltration (IP55) (det. A);
- Air vents should be fitted in both the upper and lower parts of
the columns in order to avoid condensate build up (det. B);
• Conformity with the dimensional and structural characteristics as
stipulated by good building practice
• The end structure should respect the parameters as laid down by
the standards and regulations in force UNI EN 12453 with regard
to maintaining safety conditions during the use of motorized gates
and doors.
The geared motor is normally installed with the drive shaft
pointing upwards (det. A). To position the motor with the driveshaft
pointing downwards (det. C) create a supplementary cover within
the column where necessary.
• These instructions are aimed at professionally qualified 'INSTALLERS
Description :
mber :
DI0537
OF ELECTRICAL EQUIPMENT' and must respect the local standards
AUTOMAZIONE INTEGRATO PER CANCELLI
de :
205/BLi924
and regulations in force.
A BATTENTE
eath
Date:
04-08-2010
All materials used must be approved and must suit the environment
TRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
in which the installation is situated and all maintenance operations
must be carried out by professionally qualified technicians.
• This appliance must be used exclusively for the purpose for which it
has been made. 'i.e. for the automation of hinged gates' with one
or two gate leaves.
CAUTION! Mechanical stop buffers must be installed in both
the closing and opening positions.
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the installer to make sure that the following
public safety conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from
the main road to eliminate possible traffic disruptions.
2) The motor must be installed on the inside of the property and not on
the public side of the gate. The gates must not open onto a public
area.
3) The gate operator is designed for use on gates through which vehicles
are passing. Pedestrians should use a separate entrance.
4) The controls must be installed at a height between 1,5 and 1,8 m and
in a location not accessible to children. Controls installed externally
must be protected by a safety device inhibiting unauthorised use.
ATTENTION! IMPORTANT SAFETY INSTRUCTIONS
A
C
B
5) At least two warning signs (similar to the example
on the right) should be placed, where they can be
easily seen by the public, in the area of the system
of automatic operation. One inside the property
and one on the public side of the installation.
These signs must be indelible and not hidden by any objects (such
as tree branches, decorative fencing etc.).
6) Make sure that the end-user is aware that children and/or pets must
not be allowed to play within the area of a gate installation. If possible
include this in the warning signs.
7) Whenever a fully open gate leaf comes within at 500 mm of a fixed
structure the space must be protected by an anticrush buffer.
8) You are advised to protect the system's lateral access points with
pairs of (FS) photocells connected to the stop input, see installation
example, component 14 on page 2.
9) If you have any questions about the safety of the gate operating
system, do not install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
BLi1000 self-locking unit suitable for the automation of hinged gates
with one or two gate leaves, max. length 2 m, (2,5 m with an electric
lock), max. weight 150 kg.
• The geared motor is powered by 24 Vdc and is fitted with a per-
manently lubricated four-stage epicycloid reduction unit.
• The geared motor is fitted with an Allen key operated manual
release system.
USER INSTRUCTIONS
Attention! Only for EU customers - WEEE marking.
This symbol indicates that once the products life-span has
expired it must be disposed of separately from other rubbish.
The user is therefore obliged to either take the product to a
suitable differential collection site for electronic and electrical
goods or to send it back to the manufacturer if the intention
is to replace it with a new equivalent version of the same
product.
Suitable differential collection, environmental friendly treatment and
disposal contributes to avoiding negative effects on the ambient and
consequently health as well as favouring the recycling of materials.
Illicitly disposing of this product by the owner is punishable by law and
will be dealt with according to the laws and standards of the individual
member nation.
During the opening/closing manoeuvre check for correct operation and
activate the emergency stop button in case of danger. During blackouts
the gate can be released and manually manoeuvred using the supplied
release key (see manual release page 7).
Periodically check the moving parts for wear and tear and grease if
required using lubricants which maintain their friction levels unaltered
throughout time and are suitable for temperatures of -20 to +70°C.
In case of failure or operational anomalies switch off the power at the
mains do not attempt to repair the appliance yourself.
Periodically check the correct operation of all safety devices
(photoelectric cells etc.). Eventual repair work must be carried out by
specialised personnel using original spare parts.
The appliance is not suitable for continuous operation and must be
adjusted according to the model (see technical data on page 16).
6
IN THIS
AUTOMATIC OPENING
APERTURA AUTOMATICA
FERMETURE AUTOMATISÉE
AUTOMATISCHER ÖFFNUNG
Installation company:
Serial number:
Product model:
Installation date:
®
Weight in kg:
riello elettronica group
ZVE: 572 - Mod: 04-09-2017

Publicidad

loading

Este manual también es adecuado para:

Bli1000