Pre-Operation (Continued)
STARTING (see Figure 5 for replica of actual unit decal)
1. Connect the unit to a suitable ground source (see Grounding
section).
2. Remove all electrical loads from the unit.
3. Set the unloader valve to the unloaded position (the arrow on the
unit decal is pointing towards the unloader valve's location).
4. Move fuel shut-off lever as far as possible to the right to enable
fuel flow.
5. For a cool engine, slide the choke lever to the left.
6. Turn & hold Honda engine's key to start and release when engine
starts.
7. As the engine warms up and stabilizes, slide the choke lever back
to the right.
8. Set the unloader valve to the LOADED position so that the unit
will begin to build pressure.
IMPORTANT: After each start up, allow the engine to run for 2 to
3 minutes with no load. Always refer to this Owner's manual for
operation instructions.
Engine speed is preset to provide proper
output voltage. Never attempt to modify or
adjust engine speed or output voltage.
ENGINE BREAK-IN
After initial start-up, the engine should be broken in according to
the manufacturer's instructions. Refer to the engine manual for the
proper break-in procedure.
1
Ground unit
5
Cool engine -
use choke
CHOKE
REFER TO OWNER'S MANUAL
Figure 5
2
Remove loads
6
Turn key to
start position
until engine
starts
ON
START
OFF
COMPRESSOR BREAK-IN
Open the drain valve located underneath the tank. Allow the pump to
run without a load for 30 minutes. After 30 minutes, close the drain
valve and pressure will begin to build in the tank.
SHUT-OFF
1. Shut off and remove all electrical load devices from the unit
2. Allow the engine to run for
2-3 minutes with no electrical loads.
3. Turn engine key to the OFF position.
4. Verify that the unit has completely stopped.
5. Close the fuel supply valve.
6. Allow the unit to cool before installing any covers or storing unit.
LOW OIL SHUTDOWN
A low oil shutdown switch is provided to protect the engine. When
engine oil level drops too low for proper engine operation, the low
oil shutdown switch causes the engine to shut off. If oil level is low
when attempting to start the engine, the low oil level shutdown
switch prevents the engine from starting. If engine does not start,
check oil level.
NOTE: It is important to keep the unit on a level surface. The oil level
shutdown switch can prevent the engine from starting even if oil level
is sufficient, when the unit is placed on an uneven surface.
3
Move to unload
7
Choke lever
to off
CHOKE
4
Fuel lever to on
8
Move to load
to build PSI
11