A5 Bravomatic Marking - Acqua Brevetti BravoMATIC Manual De Instrucciones

Filtro autolimpiador automático
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

A2.6 Diagnostics page
A5 BRAVOMATIC MARKING
The diagnostic page is used to display the correct operation of the filter and to carry out the
filter disinfection procedure.
DIAGNOSTICS PAGE STEPS:
2-
Access the diagnostics page
4.1 Manual step mode operation of the gearmotor
4.2 Manual continuous mode operation of the gearmotor
5-
Solenoid valves enabling/disabling (Optional)
6-
Confirm settings
Hall Sensor:
Pressure Sensor: OFF
Motor:
Rif.
Description
Solenoid 1:
1
Product name
Solenoid 2:
3
CE Marking
Mot
Ext
5
Directive 2012/19/UE RAEE, relevance of
application's field
7
Manufacturer
1- Access the diagnostics page
9
Maximum absorbed power
11
Serial number (for the guarantee form filling)
13
After Sale – Customer Assistance
Press
2.1- Manual continuous mode operation of the gearmotor
Press
2.2- Manual operation of the continuous geared motor
Press
3- Solenoid valves enabling/disabling (Optional)
Press
3- Confirm settings
Press
If the filter is not in the correct position when exiting the diagnostic page, the gearmotor will start to rotate
until the system reaches the original filtration position.
BravoMATIC - ENGLISH
BravoMATIC - FRANÇAIS
ON
OFF
OFF
OFF
Rly
MAN139 PAGE E-12
MAN139 PAGE E-14
Rif.
Description
2
Product class code
4
Level of protection
6
Compliance with
Directive 2011/65/CE RoHs
8
Protection Class
Subscription to the electricity grid
10
12
Technical Data
sequentially and hold the pressure for 7 seconds
on the indicated buttons
repeatedly to operate the gearmotor in step
mode
hold the pressure to operate the gearmotor in
continuous mode
to activate the solenoid valve (ON) or deactivate
it (OFF)
to confirm and exit the diagnostic page