INSTRUCTIONS FOR USE
permanently into the program by means of the button
Button for the working mode of the motor.
Two working modes are available: ENDODONCY, PREPARATION. In accordance with the chosen mode,
the individual items of the setting of the motor parameters are made accessible. Press the button
repeatedly to alternate between the two modes.
Mode PREPARATION enables only the normal mode at maximum torque.
Mode ENDODONCY enables all modes – NORMAL/AREV/AFWD. The button is active only if the instrument is at rest.
Button for setting the amount of cooling water (if proportional valve installed).
Press the button to start the setting mode in which the buttons whose values can be changed are
displayed in red. Change the parameter value by means of the buttons +/- . The new value is saved
temporarily (until the change of the program number) by pressing the button of the parameter being set
again or permanently into the program by means of the button
numerical keyboard after pressing the button
Button to turn the instrument light on / off.
Press the button to turn the instrument illumination on -
If the instrument allows switching two colors of the light (white / blue UV), then
Quick pressing of the button (time < 1 second) switches color of the light
Longer pressing of the button (time >= 1 second) turns the instrument light ON / OFF
Button to turn the instrument afterblow on / off.
Press the button to turn the instrument afterblow on -
The buttom is active only if the cooling is turned on.
Button to change the direction of the motor rotation.
Press the button to change the direction of the motor rotation -
position of the lever / pedal of the foot controller.
Button to change the operation mode of the pedal / lever of the foot controller.
It indicates the discrete mode of the pedal, i.e. after pressing the foot controller pedal / lever, the controlled
quantity jumps to maximum set values and does not change any more with the pedal position. By pressing
the button the following is displayed:
Pedal in analogue mode
After pressing the foot controller pedal / lever, the controlled quantity increases proportionally to the deviation
of the foot controller pedal / lever up to the maximum value at the full deviation of the foot controller pedal /
lever. The button is active only if the instrument is at rest.
Button to turn the instrument cooling on / off.
Press the button briefly to turn the set type of the cooling of the instrument on / off. By pressing and holding
the button for ca 2 seconds a „pop-up menu " is displayed with the following options:
Press the respective button to select the desired type of the cooling - water /
spray /
, or cancel the instrument cooling type by pressing the button „ESC". To save the changed type of the
instrument cooling permanently into the memory, first press the button of saving into the memory
condition of saving the data into memory is indicated by change in the colour of the icon
cancelled by pressing the button again.
Button to correct the patient position
Press the button briefly to display the screen to control the basic movements of the chair and then the patient
position can be corrected. To return, press the button ESC or activate the instrument. It is still possible to
correct patient position (while instrument is activated) with the basic moves of the chair via foot controller.
UM_EN_TYGI350B_2018-09_ver1.0
.
. The new value can be entered also directly via
. The button is active only if the instrument cooling is turned ON
/ off -
/ off -
ESC
/
and
.
. The button is active only at the rest
, or
. This condition can be