1. SPECIFICATIONS
1.1 Technical specifications
Parameter
Minimum - Maximum draught
Fuel consumption
Smoke mass flow rate
Performance
Nominal output
Power range
Average CO concentration at 13% of O2
Particle concentration
Payload (trial)
Reload interval period (trial)
Medium draft (trial)
Net weight
Maximum authorized load (fuel)
Reload height
Logs length
Minimum flue height
Flue duct
Ø Air inlet
Front safety distance
Side safety distance
Back safety distance
Primary register (trial)
Secondary register (trial)
Average temperature of smoke
Type of combustion
Flue liner
Fuel
Humidity fuel logs
Certification year
Certificate No.:
1.2 Breakdown of delivery components
(Make sure you have all the components described below in relation to the picture on section II of the ANNEXED
document)
1. Fireplace's body.
2. Flue liner connector.
3. Heat-resistant spray paint for touch-ups.
4. Body of the ceiling plate.
5. Heat-resistant glove.
6. Trim of the ceiling plate.
7. Upper baffle plate to adjust draught.
8. Bag with screws and anchors.
9. Aluminium ring to connect.
10. The body of the telescopic ceiling plate.
11. Fixative of the aluminium ring.
12. Tool for handling registers and opening door.
13. Metal clamp.
14. Exterior air inlet cover.
15. Bag with metallic anchors.
16. Cleaning cloth.
17. Envelope with 3 documents: specifications, installation and operation manual, and Guarantee sheet.
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I, page 1.
Value
11-13 Pa
2,3 kg/h
11 g/s
7,8 kW
5 - 9 kW
0,12%
27 mg/Nm
2,1 kg
50 min
101 kg
3,5 kg
200 mm
300 mm
4000 mm
180 mm
100 mm
1000 mm
300 mm
500 mm
5 mm open
35 mm open
144º C
INTERMITTENT
NOT SHARED
NATURAL WOOD
12-20% - two years under cover
CEE-0001/16-1
83 %
3
12 Pa
2016
pag. 10