3 - Installation instructions
EN
Installation
these instructions are aimed at qualified fitters as a guide to
installation, adjustment and maintenance in compliance with the
laws and standards in force. The operations must always be carried
out with the appliance disconnected from the electricity supply.
Positioning (Fig. 6-7)
The appliance is made to be fitted into a counter top, as show in the
figure. Apply the sealant supplied around the whole perimeter of
the hob. Installation over an oven is not recommended, but if this is
necessary, check that:
• the oven has an efficient cooling system;
• there is no passage of hot air from the oven to the hob;
• allow air passages as shown in the figure.
INDU Z IO NE
10
50 MIN.
induzione - induction - induction - Induktion
- inducción - inductie - indução
ZONA FORNO O ARMADIETTO
OVEN ZONE OR CUPBOARD
ZONE FOUR OU PLACARD
OFENBEREICH ODER SCHRANK
ZONA HORNO O ARMARIO
OVENRUIMTE OF KASTJE
ZONA DO FORNO OU ARMÁRIO
50 MIN.
INDU C TIO N
INDU CC IØN
INDU ÎÍ O
Electrical connection (Fig. 8)
Before connecting to the electricity supply, ensure that:
• the characteristics of the system are such as to satisfy that
indicated on the registration plate applied to the bottom of the
hob;
• the system has an effective earth connection compliant with the
standards and laws in force. Connection to earth is compulsory
by law.
If the appliance has no cable and/or plug, use material suitable
for the absorption indicated on the registration plate and for the
working temperature. The cable must not reach a temperature
higher than 50°C above room temperature in any point.
For direct connection to the network it is necessary to fit an omnipolar
switch of a suitable size to ensure disconnection of he network with
a contact opening distance that allows complete disconnection in
the conditions of the overtension category III, compliant with the
installation regulations (the yellow/green earth wire must not be
interrupted).
The omnipolar socket or switch must be easy to reach when the
appliance is installed.
N.B.:
• The manufacturer declines all responsibility if the usual accident
prevention standards and the above instructions are not
observed.
If the power cable is damaged, it must be replaced by the
manufacturer or by the manufacturer's technical servicing network,
or by a similarly qualified operator, to prevent every possible risk.
Fig. 6
aria - air - air - Luft - aire - lucht - ar
100 cm
MIN.
2
(2 x 500)
aria - air - air - Luft - aire - lucht - ar
100 cm
2
MIN.
POSITION OF SEALANT IN THE

SEMI FLUSH WITH TOP VERSION


