Control Techniques Commander SE11200025 Guia Del Usuario página 13

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

AC supply voltage and frequency
Input displacement factor (cos φ)
Nominal motor power - kW
Nominal motor power - hp
Output voltage and frequency
100% RMS output current - A
150% overload current for 60 secs - A
Typical full load input current - A*
Typical inrush current - A** (duration <10ms)
Drive power losses at 230Vac at 6kHz switching
frequency - W
Weight - kg/lb
Cooling fan fitted
* See section 3.1.1.
** For an explanation of inrush current, see section 3.1.2.
Recommended input supply fuse - A
Control cable
Recommended input cable
Recommended motor cable
Recommended braking resistor cable
*It is recommended that 6mm
length greater than 100m are used
Minimum braking resistor value - Ω
Recommended braking resistor value - Ω
Resistor peak power rating - kW*
* Based on recommended braking resistor value.
** Absolute minimum braking resistor value.
Before fitting a braking resistor please read the information on Braking, and the
NOTE
Warnings on High Temperatures and Overload Protection at the end of this
section.
Commander SE User Guide
Issue Number 9
MODEL
Table 3.12 Commander SE Size 3, 200V units
MODEL
Table 3.13 Recommended fuses and cables
2
/ 8AWG cable is used to minimise volt drops when cable
MODEL
**
Table 3.14 Braking Resistors
www.controltechniques.com
SE33200...
550
3 phase 200 to 240V +/-10%, 48 to 62Hz
>0.97
5.5
7.5
3 phase, 0 to input voltage, 0 to 1000Hz
25.0
37.5
22.8
230
6 / 13.2
SE33200...
550
mm²
AWG
mm²
AWG
mm²
AWG
mm²
AWG
SE33200...
550
750
7.5
10.0
28.5
42.8
24.6
44
305
Yes
750
30
>0.5
20
4.0*
10*
4.0*
10*
4.0
10
750
12.0
15.0
11.8
13

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido