A power surge has been detected.
US2
An undervoltage has been detected.
A phase of the electricity network is
US3
missing
The trigger of the torch is at fault but still
Err
USc
active.
Err
HAD
A defect on the VRD was found.
Err
HAP
A hard fault is detected.
Err
Ebp
A button on the keypad is defective.
A problem with the presence of the
CU
001
cooling unit is detected.
A liquid flow problem has been detec-
CU
002
ted.
CU
003
A coolant level problem is detected.
If an error code which is not listed appears or your problems persist, contact your distributor.
WARRANTY CONDITIONS
The warranty covers any defects or manufacturing faults for two years from the date of purchase (parts and labour).
The warranty does not cover:
• Any other damage caused during transport.
• The general wear and tear of parts (i.e. : cables, clamps, etc.).
• Incidents caused by misuse (incorrect power supply, dropping or dismantling).
• Environment-related faults (such as pollution, rust and dust).
In the event of a defect, return the equipment to your distributor, enclosing:
- dated proof of purchase (receipt, invoice, etc.),
- a note explaining the malfunction.
46
Translation of the original
instructions
The product has gone into a protective
mode.
The trigger of the torch is defective.
-
A problem has been detected on the
DSP or on the thermal disconnection
of the SAM robotic module.
A button on the keypad is short-cir-
cuited.
The cooling unit was detected by the
product, but then the information was
lost.
The pump does not start (no sound).
The pump works (noise) but there is
no liquid circulation.
There is no coolant in the tank.
KRYPTON 231 DC FV / 321 DC TRI
Check the wiring of the power outlet and
the tightness of the terminals.
If the overvoltage is only temporary, the
product will resume operation after 15
seconds.
Remove the torch and check if the mes-
sage is still accurate.
If so, torch fault.
If not, check the internal connections.
Contact your distributor.
Check the wiring.
Replace the keypad.
Check the connections between the cooling
unit and the product (connector properly
fitted and plugs securely mounted...).
Check the connections between the cooling
unit and the product (connector properly
fitted and plugs securely mounted...).
The pump is out-of-order and must be
replaced.
The electronic control board inside the
cooling unit is out of order and needs to be
replaced.
The pump is not primed, perform a forced
priming procedure by putting a hose or
a torch directly between the water outlet
(blue) and the container spout.
The coolant circuit is blocked, the torch is
out of order.
Check the connections between the cooling
unit and the product (connector properly
fitted and plugs securely mounted...).
The flow sensor is defective and must be
replaced.
The electronic control board inside the
cooling unit is out of order and needs to be
replaced.
Check the coolant level and top up to the
MAX level indicated on the product.
Check the connection between the coolant
level sensor and the control board inside
the cooling unit.