Connection of inputs:
Circuit
Name
board
Main
ºC
Main
COVER / AUX
FL1 / FLOW
Main
SWITCH
Main
SLAVE
Main
PH
Main
FILTER PUMP
Main
LIGHT 50W
VARIABLE
Main
SPEED PUMP
Main
SCREEN
Main
WIFI
Main
EXTERN
Main
PH
Main
RX
Extension
ION
Extension
TANK1
Extension
TANK2
Extension
FL2 CL2
Extension
AUX1
Extension
AUX2
Extension
AUX3
Extension
AUX4
Extension
4-20mA LOOP1 Reading from free chlorine sensor equipped with membrane
Extension
4-20mA LOOP2 Reading from 4-20 mA probe
Extension
CD
Extension
CL2
Extension
CL POWER
Extension
CL
Extension
CD
3d. Cabling the box
6 inputs for equipment cables
Drill using an M12 bit
or a tapered bit
Power cable
Gas detector
Description
Temperature probe (optional)
Pool shutter position sensor
Mechanical flow switch
Terminal for master or slave box
Peristaltic or electromagnetic injection pump
Control of filtration pump
Control and power supply for lighting
Control of variable speed pump
Remote screen (optional)
WiFi or Ethernet module (optional)
Standard communication connector
pH Connection chip (optional), with markings and LED on the left
ORP Connection chip (optional) with markings and LED on the left
Connector for power supply to copper electrode (not provided)
Empty container sensor 1
Empty container sensor 2
Flow switch for free chlorine sensor
UV Module
Control and power supply by relay
Control by relay
Control of heat pump (temperature option) or control by relay
Connection of conductivity probe
Connection of amperometric free chlorine sensor
CL Connection chip (optional) with markings and LED on the left
CD Connection chip (optional) with markings and LED on the left
Cell power supply
AquaRite
UV LS
®
Only use spare parts supplied by Hayward brands
Terminals Type of input / output
A-B-C
D-F
E-F
G-F
H-I
J-K
L-M
N-O-P-Q
R
S
T
U
V
3-6
4-6
5-6-7
for amperometric
5-6
for membrane
8-9
10-11
12-13
14-15
16-17
18-19
20
21-22
23-24
25
26
WiFi / Ethernet module
Drill using an M16.5 bit
or a tapered bit
ORP probe
Page 7 on 22
®
Red, yellow, black
Dry contact
Non-polarised dry contact
Dry contact
Output: Voltage 230 VAC 5A max
Dry contact
Output: Voltage 12 VAC 50W max
Dry contact
V1 - V2 - V3 - Common
Modbus RS465
From top to bottom: red/free/yellow/green/black
Modbus RS465
From top to bottom: red/free/yellow/green/black
Modbus RS465
From top to bottom: red/free/yellow/green/black
5 VDC
5 VDC
Dry contact
Dry contact
Black - brown - blue
Black - red
Output: Voltage 230 VAC 5A max
Output: Voltage 230 VAC 5A max
Dry contact
Dry contact
+: green (+12 VAC) /
-: yellow (4-20mA)
12 VAC 4-20mA
5 VDC
5 VDC
pH probe