Calibration of free chlorine: It is recommended
to do this once a month during the season the
pool is in use.
2
Calibration using reference values (DPD1
photometer): Follow the 6-step instructions that
appear on the display screen (points 4 to 7).
3
Manual calibration: Open the water intake and
wait until the free chlorine value displayed on the
unit screen is stable. With the up/down buttons,
adjust the value displayed until it coincides with
the free chlorine value measured during the
DPD1 analysis (in ppm), then press OK.
4
Step 1 of 6 - CL calibration of 1st point
(0 ppm): Stop the flow of water through the
sensor and wait until the value displayed on the
6f. Installing and starting up the free chlorine option (membrane sensor)
Always begin the calibration procedure with a calibration reset.
Please contact your dealer for configuration of the free chlorine sensor equipped with a membrane.
We recommend calibrating the free chlorine sensor with a high chlorine level: between 1ppm and 1.2ppm.
1
Open the cover and connect the CL CHIP card to the CL slot (see section 3C).
The chlorine reading and the Measures menu will be displayed automatically, to
configure the setpoint and carry out the calibration.
2
Configure the 4-20 mA membrane sensor in the service menu.
3
Place the sensor in a bypass, following the sensor instructions.
4
Connect the 3 cables of the floater to the extension circuit board (see section 3C).
5
Connect the 2 cables of the sensor to the extension circuit board (see section 3C).
1
1
Calibration of the free chlorine sensor equipped with a membrane: It is
recommended to do this once a week during the season the pool is in use.
2
Before beginning the calibration, measure the pool free chlorine (in ppm) by
performing a DPD1 analysis and click on Test DPD1.
6g. Installing the WiFi or Ethernet module
1
Open the cover and connect the WiFi module to the WIFI slot (see section 3C). The Network menu appears automatically in the Settings menu. The power LED remains
steady and the connection LED flashes
1
2
1
Internet: Once the module is connected, switch on the device. A Network menu
appears in the Settings menu.
2
Wifi: Select the Wifi menu to start an automatic search for available networks.
3
Choose the relevant available network.
4
Enter the password for this network via the keyboard. To confirm, press OK.
unit screen drops below 0.10 ppm (between
5 and 60 minutes). Press OK when the value is
close to 0.
5
Step 3 of 6 - CL calibration of 2nd point:
Open the water intake to a rate of 80-100 litres/h
then wait until the free chlorine value is stable
(between 5 and 20 minutes). Press OK when the
value is stable.
6
Step 5 of 6 - With the up/down
the displayed value until it coincides with the
free chlorine concentration measured during the
DPD1 analysis (in ppm) then press OK.
7
Step 6 of 6 - If this screen does not appear,
repeat the calibration process.
2
3
3
AquaRite
UV LS
®
Only use spare parts supplied by Hayward brands
5
buttons,
adjust
6
Leave the sensor to polarise for at least 24h.
7
Start sensor calibration after 24h in operation.
i
The flow through the transparent mount must be constant to ensure optimum
reading.
i
The sensor has a lifetime of 1 year. We recommend calibrating it every month
during the season the pool is in use.
4
3
Step 1 of 3: Enter the value measured during the DPD1 analysis and press OK.
4
Step 3 of 3: Press OK to validate the calibration.
4
5
5
Configuration: If you want to configure your connection manually or if automatic
configuration fails, you can change the network parameters in this menu.
6
The default setting "DHCP = ON" must be left as it is.
7
Status: Displays information about your current connection.
Page 18 on 22
®
4
4
.1
.2
5
6
.1
.2
ppm Cl2
10
5
0
4
12
6
4
.3
7
mA
20
7

Publicidad

loading