Problems
Signals
STATUS
EASY-SMALL
START
will not turn on
STOP
POWER
STATUS
START
STOP
POWER
STATUS
START
STOP
POWER
STATUS
START
STOP
The pump will
POWER
not start when
a tap is turned on
STATUS
START
STOP
POWER
STATUS
START
STOP
POWER
The pump
STATUS
delivers no or low
START
STOP
pressure
POWER
STATUS
The pump stops
START
and starts
STOP
repeatedly
POWER
The pump will
not stop
= Off
= On
Disposal
When disposing of any EASY-
SMALL parts, adhere to the
relevant laws and regulations
in force in the country in
which the equipment is
being used.
Do not dispose
of any polluting
parts in the
environment.
Possible causes
No power
EASY-SMALL model with an inade-
quate start-up pressure (Pm) for the
chosen application.
Faulty electrical connections or
pump out of service
EASY-SMALL "OUT OF SERVICE"
EASY-SMALL in temporary shut down
due to "DRY RUNNING" due to lack
of water
Maximum pump pressure is
insufficien
EASY-SMALL in temporary shut down
due to "FREQUENT START-UP"
Filters or pipes may be partly blocked Check the water pipes
EASY-SMALL's valve will not open
completely
Leaks within the system (less than
STATUS
the shut-off flow rate Qa
START
STOP
POWER
The flow rate is higher than the
shut-off flow rate (Qa
STATUS
START
STOP
EASY-SMALL's check valve will not
POWER
close
Statement of Compliance: we declare, under our own responsibi-
lity, that the product in question is in compliance with the following
European Directives and national implementation provisions
2014/35/CE, 2011/65/CE,
2012/19/CE, 2003/108/CEE,
2014/30/CE,
EN 60730-2-6, EN 61000 6-3
UK legislation:
2016 No. 1101, 2012 No. 3032,
2016 No. 1091
Solutions
Check the electrical connections
Relocate EASY-SMALL to another position
Install a model with a higher start-up pressure (Pm)
Check the electrical connections and that the pump
is working
Reset EASY-SMALL (See Operation, point 3).
Wait for the automatic restart or press START to
restart manually (See Operation, point 4a)
Replace the pump with one with more suitable
characteristics
Install a model with a lower start-up pressure (Pm)
Wait for the automatic restart or press START to
restart manually (See Operation, point 4b). Remove
any cause of leakage from system or install an
expansion tank
Check that the valve is not blocked by any foreign
objects and clean if necessary
Check the hydraulic connections and repair any
leaks. If a leak cannot be repaired, install an
expansion tank
Make sure that all taps are turned off and that
there are no leaks within the system
Check that the valve is not blocked by any foreign
objects and clean if necessary
= Flashing
San Bonifacio 01.07.21
PEDROLLO SpA
President
Silvano Pedrollo
= Flashing
Made in Italy by
SpA
Via Enrico Fermi, 7
37047 San Bonifacio (Verona) ITALY
Tel +39 045 6136311
Fax +39 045 7614663
sales@pedrollo.com