Owner´s manual
Instructions on AC Usage
NOTE:
Acquaint yourself with the parameters on the control panel to ensure correct usage within the
rated output of the generator set.
CAUTION: The generator set can work at its rated output only under constant temperature, pressure
and humidity. The variation of temperature, pressure and humidity may influence the output of the
generator. The temperature range in which the unit can be started is 15C
Surrounding temperature: 15C0-40C0
Surrounding pressure: 100kPa
Relevant Humidity: 30%
Height above Sea Level: 1000m
Start the generator, connect the devices. The generator can supply 110/220V AC, (depending on your
model) set the voltage selector (if there is such a selector) to the position suitable to equipment. If the
generator is not equipped with a voltage selector, there will be sockets of 110V and 220V respectively
(according to the acquired model), please plug the load wire in the relevant sockets suitable for the loads.
Turn on the AC breaker.
6. STOPPING THE ENGINE
In case of emergency
Set the ignition switch to OFF position directly to stop the generator.
Under normal conditions
Turn off the AC circuit breaker and unplug all outlets. Run the unit unloaded for a few minutes to allow
the generator to cool down. Turn the power switch to the OFF position (Figure 1). Close the fuel cock, OFF
position (Picture 2).
Image 1
WARNING. Don't touch any of the components that get hot until the unit is turned off and has cooled
down completely to avoid burns.
CAUTION. Fuel storage in unit which is not to be used for long time will cause it difficult to start the
engine. Drain the fuel for long-time storage of the unit.
32
Image 2
-40C
. The standard condition is: