HOW THE AIR CONDITIONER WORKS

Automatic Operation
As shown in Figures 1 and 2, Automatic Operation mode selects the operation based on the room temperature data (Ta) when
operation begins.
Heat pump models
Room temperature when operation begins
or when selected again
Room temperature
Cooling operation
Setting temperature+1
Setting temperature
Fan only operation
Setting temperature–1
Heating operation
The operation mode is selected again after the compressor has remained stopped for 15 minutes.
Hi POWER operation
When you press the Hi POWER button during cooling, heating or A operation, the air conditioner starts the following operation.
• Cooling operation
The cooling operation is performed at 1°C lower than the temperature setting.
When the room temperature is higher than the temperature setting, the air flow is directed downward. The fan speed is also set to
high*. Once the room temperature is within 1°C of the temperature setting, the air flow is returned to its previous direction.
* The noise level raises, according to the fan speed.
• Heating operation (heat pump models)
The heating operation is performed at 2°C higher than the temperature setting.
The air flow direction and fan speed are automatically switched according to the operating condition.

ECO operation

When you press the ECO button during cooling, heating or A operation, the air conditioner starts the following operation.
The fan speed is controlled automatically.
• Cooling operation (
)
In the minimum operation zone, where the air conditioner is operated at minimum capacity, overcooling is prevented by raising the
temperature setting.
The room temperature is thus regulated between the minimum operation zone and the temperature setting.
• Heating operation (
) (heat pump models)
In the minimum operation zone, where the air conditioner is operated at minimum capacity, overheating is prevented by lowering the
temperature setting.
The room temperature is thus regulated between the temperature setting and the minimum operation zone.
EN
Figure 1
www.ilmalämpöpumput.com
Cooling-only models
Room temperature when operation begins
or when selected again
Room temperature
Cooling operation
Setting temperature+1
Setting temperature
Fan only operation
Figure 2
16