Malfunction at the dimmable socket:
Malfunction
A connected unit cannot be
switched on or dimmed.
A connected light is flickering or
the dimmer is humming.
Malfunction of the OASE control function:
Malfunction
A unit, which is connected to the
InScenio FM-Master Home, Cloud
to the OC-connection, does not re-
spond to commands.
32
Possible cause
The unit is not dimmable.
Load of the unit is less than the
minimum load of the dimmer.
The fine-wire fuse has tripped.
Load is not dimmable.
Load is less than the minimum load
of the dimmer.
Possible cause
The data cable is interrupted.
The data cable is damaged.
OC-Network not completed.
OC-Unit without power supply.
Remedy
Connect a unit compatible with the
dimmer. (→ Connect the units to
the power supply distributor).
Increase load.
Replace the fine-wire fuse.
Connect a unit compatible with the
dimmer. (→ Connect the units to
the power supply distributor).
Increase load (e.g. connect more
lights).
Remedy
Check the plug connections.
Check the data cable.
At the last OC-unit, plug the termi-
nal resistor.
Establish the power supply.